beautypg.com

Enabling a chassis, Switch and backbone shutdown, Powering off a brocade switch – Brocade Fabric OS Administrators Guide (Supporting Fabric OS v7.3.0) User Manual

Page 61

background image

All Fibre Channel ports on all logical switches are taken offline. If the logical switches are in fabrics,
the fabrics are reconfigured.

NOTE
After a chassisDisable , if you want to do an haFailover , you should wait at least 30 seconds.

Enabling a chassis

Enabling a chassis enables all Fibre Channel ports on all logical switches in the chassis. The chassis is
enabled by default after it is powered on and switch initialization routines have finished. You must re-
enable the chassis after making fabric-wide configuration changes or running offline diagnostics.

1. Connect to the switch and log in using an account assigned to the admin role.
2. Enter the chassisEnable command.

switch:FID128:admin> chassisenable

For all logical switches in the chassis, all Fibre Channel ports that passed Power On Self Test
(POST) are enabled. If any of the logical switches have inter-switch links (ISLs) to a fabric, it joins the
fabric.

Switch and Backbone shutdown

To avoid corrupting your file system, you must perform graceful shutdowns of Brocade switches and
Backbones.

Warm reboot (also known as graceful shutdown ) refers to shutting down the switch or platform by way
of the following instructions. Cold boot (also known as a hard boot ) refers to shutting down the switch
or platform by suddenly shutting down power and powering on again.

Powering off a Brocade switch

Use the following procedure to gracefully shut down a Brocade switch.

1. Connect to the switch and log in using an account assigned to the admin role.
2. Enter the sysShutdown command.
3. Enter y at the prompt.

switch:admin> sysshutdown

This command will shutdown the operating systems on your switch.

You are required to power-cycle the switch in order to restore operation.

Are you sure you want to shutdown the switch [y/n]?y

4. Wait until the following message displays:

Broadcast message from root (ttyS0) Wed Jan 25 16:12:09 2006...

The system is going down for system halt NOW !!

INIT: Switching to runlevel: 0

INIT: Sending processes the TERM signal

Unmounting all filesystems.

The system is halted

flushing ide devices: hda

Power down.

5. Power off the switch.

Enabling a chassis

Fabric OS Administrators Guide

61

53-1003130-01