beautypg.com

Brocade Fabric OS Administrators Guide (Supporting Fabric OS v7.3.0) User Manual

Page 561

background image

zone config "zone_cfg" is in effect

Updating flash ...

6. Log in as admin to fabric2.
7. Enter the nsShow command to list Target A (50:05:07:61:00:5b:62:ed) and Target B

(50:05:07:61:00:49:20:b4).

switch:admin> nsshow

{

Type Pid COS PortName NodeName TTL(sec)

NL 0508e8; 3; 50:05:07:61:00:5b:62:ed; 50:05:07:61:00:1b:62:ed; na

FC4s: FCP [IBM DNEF-309170 F90F]

Fabric Port Name: 20:08:00:05:1e:34:11:e5

Permanent Port Name: 50:05:07:61:00:5b:62:ed

NL 0508ef; 3; 50:05:07:61:00:49:20:b4; 50:05:07:61:00:09:20:b4; na

FC4s: FCP [IBM DNEF-309170 F90F]

Fabric Port Name: 20:08:00:05:1e:34:11:e5

Permanent Port Name: 50:05:07:61:00:49:20:b4

LSAN: Yes

The Local Name Server has 2 entries }

8. Enter the zoneCreate command to create the LSAN "lsan_zone_fabric2", which includes the host

(10:00:00:00:c9:2b:6a:2c), Target A, and Target B.

switch:admin> zonecreate "lsan_zone_fabric2", "10:00:00:00:c9:2b:c9:0c;

50:05:07:61:00:5b:62:ed;50:05:07:61:00:49:20:b4"

9. Enter the cfgShow command to verify that the zones are correct.

switch:admin> cfgshow

Defined configuration:

zone: lsan_zone_fabric2

10:00:00:00:c9:2b:c9:0c; 50:05:07:61:00:5b:62:ed;

50:05:07:61:00:49:20:b4

Effective configuration:

no configuration in effect

10.Enter the cfgAdd and cfgEnable commands to create and enable the LSAN configuration.

switch:admin> cfgadd "zone_cfg", "lsan_zone_fabric2"

switch:admin> cfgenable "zone_cfg"

You are about to enable a new zoning configuration.

This action will replace the old zoning configuration with the

current configuration selected.

Do you want to enable 'zone_cfg' configuration (yes, y, no, n): [no] y

zone config "zone_cfg" is in effect

Updating flash ...

11.Log in as admin and connect to the FC router.
12.Enter the following commands to display information about the LSANs:

lsanZoneShow -d displays the fabric ID of the LSAN devices and whether the device physically

exists in the fabric or is imported from another fabric.

switch:admin> lsanzoneshow -d

Fabric ID: 2 Zone Name: lsan_zone_fabric2

10:00:00:00:c9:2b:c9:0c Imported from FID 75

50:05:07:61:00:5b:62:ed EXIST in FID 2

50:05:07:61:00:49:20:b4 EXIST in FID 2

Fabric ID: 75 Zone Name: lsan_zone_fabric75

10:00:00:00:c9:2b:c9:0c EXIST in FID 75

50:05:07:61:00:5b:62:ed Imported from FID 2

fcrPhyDevShow shows the physical devices in the LSAN.

switch:admin> fcrphydevshow

Device WWN Physical

Exists PID

in Fabric

-----------------------------------------

75 10:00:00:00:c9:2b:c9:0c c70000

2 50:05:07:61:00:49:20:b4 0100ef

Using FC-FC Routing to Connect Fabrics

Fabric OS Administrators Guide

561

53-1003130-01