Brocade Fabric OS Administrators Guide (Supporting Fabric OS v7.3.0) User Manual
Page 561
zone config "zone_cfg" is in effect
Updating flash ...
6. Log in as admin to fabric2.
7. Enter the nsShow command to list Target A (50:05:07:61:00:5b:62:ed) and Target B
(50:05:07:61:00:49:20:b4).
switch:admin> nsshow
{
Type Pid COS PortName NodeName TTL(sec)
NL 0508e8; 3; 50:05:07:61:00:5b:62:ed; 50:05:07:61:00:1b:62:ed; na
FC4s: FCP [IBM DNEF-309170 F90F]
Fabric Port Name: 20:08:00:05:1e:34:11:e5
Permanent Port Name: 50:05:07:61:00:5b:62:ed
NL 0508ef; 3; 50:05:07:61:00:49:20:b4; 50:05:07:61:00:09:20:b4; na
FC4s: FCP [IBM DNEF-309170 F90F]
Fabric Port Name: 20:08:00:05:1e:34:11:e5
Permanent Port Name: 50:05:07:61:00:49:20:b4
LSAN: Yes
The Local Name Server has 2 entries }
8. Enter the zoneCreate command to create the LSAN "lsan_zone_fabric2", which includes the host
(10:00:00:00:c9:2b:6a:2c), Target A, and Target B.
switch:admin> zonecreate "lsan_zone_fabric2", "10:00:00:00:c9:2b:c9:0c;
50:05:07:61:00:5b:62:ed;50:05:07:61:00:49:20:b4"
9. Enter the cfgShow command to verify that the zones are correct.
switch:admin> cfgshow
Defined configuration:
zone: lsan_zone_fabric2
10:00:00:00:c9:2b:c9:0c; 50:05:07:61:00:5b:62:ed;
50:05:07:61:00:49:20:b4
Effective configuration:
no configuration in effect
10.Enter the cfgAdd and cfgEnable commands to create and enable the LSAN configuration.
switch:admin> cfgadd "zone_cfg", "lsan_zone_fabric2"
switch:admin> cfgenable "zone_cfg"
You are about to enable a new zoning configuration.
This action will replace the old zoning configuration with the
current configuration selected.
Do you want to enable 'zone_cfg' configuration (yes, y, no, n): [no] y
zone config "zone_cfg" is in effect
Updating flash ...
11.Log in as admin and connect to the FC router.
12.Enter the following commands to display information about the LSANs:
• lsanZoneShow -d displays the fabric ID of the LSAN devices and whether the device physically
exists in the fabric or is imported from another fabric.
switch:admin> lsanzoneshow -d
Fabric ID: 2 Zone Name: lsan_zone_fabric2
10:00:00:00:c9:2b:c9:0c Imported from FID 75
50:05:07:61:00:5b:62:ed EXIST in FID 2
50:05:07:61:00:49:20:b4 EXIST in FID 2
Fabric ID: 75 Zone Name: lsan_zone_fabric75
10:00:00:00:c9:2b:c9:0c EXIST in FID 75
50:05:07:61:00:5b:62:ed Imported from FID 2
• fcrPhyDevShow shows the physical devices in the LSAN.
switch:admin> fcrphydevshow
Device WWN Physical
Exists PID
in Fabric
-----------------------------------------
75 10:00:00:00:c9:2b:c9:0c c70000
2 50:05:07:61:00:49:20:b4 0100ef
Using FC-FC Routing to Connect Fabrics
Fabric OS Administrators Guide
561
53-1003130-01