FIGURE 81 Switch in Access Gateway mode with F_Port masterless trunking

NOTE
You do not need to map the host to the master port manually because the Access Gateway will
perform a cold failover to the master port.

Refer to

Configuring F_Port trunking for an Access Gateway

on page 520 for instructions on

configuring F_Port trunking.

Requirements for F_Port trunking on an Access Gateway

In addition to the requirements listed in

Requirements for trunk groups

on page 512, refer to the

Access Gateway Administrator's Guide for additional requirements that are specific to F_Port trunking
on an Access Gateway.

Configuring F_Port trunking for an Access Gateway

Access Gateway trunking configuration is mostly on the edge switch. On the Access Gateway module,
you only need to ensure that the Trunking license is applied and enabled.

Use the following procedure on the edge switch connected to the Access Gateway module to
configure F_Port trunking.

1. Connect to the switch and log in using an account assigned to the admin role.
2. Enter the portCfgShow command to ensure that the ports have trunking enabled. If trunking is not

enabled, enter the portCfgTrunkPortport1 command.

3. Enter the portDisable command for each port to be included in the TA.
4. Enter theportTrunkArea --enable command to enable the trunk area.

Requirements for F_Port trunking on an Access Gateway