For related FC-FC routing commands, refer to fcrEdgeShow, fcrXlateConfig, fcrConfigure, and
fcrProxyConfig in the Fabric OS Command Reference.

A Fibre Channel router can interconnect multiple fabrics. EX_Ports or VEX_Ports attached to more
than one edge fabric must configure a different fabric ID for each edge fabric.

3. (Optional ) Configure FC router port cost if you want to change the default values. For information

about using FC router port cost operations, refer to

FC router port cost configuration

on page 553.

4. (Optional ) Set up ISL or EX_Port trunking. For information on trunking setup, refer to

Configuring

EX_Port trunking

on page 518.

5. Enter the portEnable command to enable the ports that you disabled in step 1.

switch:admin> portenable 7/10

6. Physically attach ISLs from the Fibre Channel router to the edge fabric.
7. Enter the portCfgShow command to view ports that are persistently disabled.

FC ports on the Brocade 7800 and 7840 switches and FX8-24 blades are configured as persistently
disabled by default to avoid inadvertent fabric merges when installing a new FC router.

switch:admin> portcfgshow 7/10

Area Number: 74

Speed Level: AUTO

Trunk Port OFF

Long Distance OFF

VC Link Init OFF

Locked L_Port OFF

Locked G_Port OFF

Disabled E_Port OFF

ISL R_RDY Mode OFF

RSCN Suppressed OFF

Persistent Disable OFF

NPIV capability ON

EX Port ON

Mirror Port ON

FC Fastwrite ON

8. After identifying such ports, enter the portCfgPersistentEnable command to enable the port, and

then the portCfgShow command to verify the port is enabled.

switch:admin> portcfgpersistentenable 7/10

switch:admin> portcfgshow 7/10

Area Number: 74

Speed Level: AUTO

Trunk Port OFF

Long Distance OFF

VC Link Init OFF

Locked L_Port OFF

Locked G_Port OFF

Disabled E_Port OFF

ISL R_RDY Mode OFF

RSCN Suppressed OFF

Persistent Disable OFF

NPIV capability ON

EX Port ON

Mirror Port ON

FC Fastwrite ON

9. Enter either the portCfgEXPort or portShow command to verify that each port is configured

correctly.

switch:admin> portcfgexport 7/10

Port 7/10 info

Admin: enabled

State: NOT OK

Pid format: Not Applicable

Operate mode: Brocade Native

Edge Fabric ID: 30

Preferred Domain ID: 160

Front WWN: 50:06:06:9e:20:38:6e:1e

Fabric Parameters: Auto Negotiate

R_A_TOV: Not Applicable

E_D_TOV: Not Applicable

Using FC-FC Routing to Connect Fabrics

Fabric OS Administrators Guide

549

53-1003130-01