beautypg.com

Brocade Fabric OS Administrators Guide (Supporting Fabric OS v7.3.0) User Manual

Page 552

background image

The following example configures EX_Port on one of the QSFP ports.

switch:admin> portcfgexport 6/20 -a 1 -f 45

2013/04/25-21:21:54, [FCR-1071], 29805, SLOT 4 | FID 2, INFO, Pluto, Port 6/20 is

changed from non FCR port to FCR port.

2013/04/25-21:21:54, [FCR-1071], 29806, SLOT 4 | FID 2, INFO, Pluto, Port 6/21 is

changed from non FCR port to FCR port.

2013/04/25-21:21:55, [FCR-1071], 29807, SLOT 4 | FID 2, INFO, Pluto, Port 6/22 is

changed from non FCR port to FCR port.

2013/04/25-21:21:55, [FCR-1071], 29808, SLOT 4 | FID 2, INFO, Pluto, Port 6/23 is

changed from non FCR port to FCR port.

4. (Optional ) Configure FC router port cost if you want to change the default values. For information

about using FC router port cost operations, refer to

FC router port cost configuration

on page 553.

5. Enter the portEnable command to enable the QSFP ports that you disabled in step 1.

switch:admin> portenable 6/20-23

6. Enter either the portCfgEXPort or portShow command to verify that each port is configured

correctly.

switch:admin> portcfgexport 6/20

Port 6/20 info

Admin: enabled

State: OK

Pid format: Not Applicable

Operate mode: Brocade Native

Edge Fabric ID: 50

Preferred Domain ID: 160

Front WWN: 50:00:51:e7:54:c0:0e:32

Fabric Parameters: Auto Negotiate

R_A_TOV: Not Applicable

E_D_TOV: Not Applicable

Authentication Type: None

DH Group: N/A

Hash Algorithm: N/A

Edge fabric's primary wwn: N/A

Edge fabric's version stamp: N/A

7. Enter the switchShow command to verify the EX_Port and edge fabric ID are correct.
8. Enter the fcrEdgeShow command to display the FIDs of all configured EX_Ports.

switch:admin> fcredgeshow

FID EX-port E-port Neighbor Switch (PWWN, SWWN )

------------------------------------------------------------------------

50 3/12 1180 50:00:51:e4:8f:8f:74:9c 10:00:00:05:1e:48:f8:00

50 3/13 1181 50:00:51:e4:8f:8f:74:9d 10:00:00:05:1e:48:f8:00

50 3/14 1182 50:00:51:e4:8f:8f:74:9e 10:00:00:05:1e:48:f8:00

50 3/15 1183 50:00:51:e4:8f:8f:74:9f 10:00:00:05:1e:48:f8:00

9. Enter the fcrIclPathBwMonitor command to monitor and report path bandwidth imbalances for

each edge fabric.

The following example enables the monitoring and reporting of bandwidth balances and
imbalances, and displays the ICL path bandwidth state for each fabric.

switch:admin> fcriclpathbwmonitor --show

ICL Path Bandwidth state :Disabled

switch:admin> fcriclpathbwmonitor --enable

ICL bandwidth balance functionality is enabled

Pluto:FID2:root> fcriclpathbwmonitor --show

ICL Path Bandwidth state :Enabled

FABRIC SLOT-3 BW SLOT-6 BW STATE

===============================================

48 128 128 BALANCED

126 64 128 UNBALANCED

Using FC-FC Routing to Connect Fabrics

552

Fabric OS Administrators Guide

53-1003130-01