Effective configuration:

cfg: cfg_TI

zone: lsan_t_i_TI_Zone1

10:00:00:00:00:00:02:00:00

10:00:00:00:00:00:03:00:00

10:00:00:00:00:00:08:00:00

E1switch:admin> cfgenable cfg_TI

You are about to enable a new zoning configuration.

This action will replace the old zoning configuration with the

current configuration selected.

If the update includes changes to one or more traffic isolation zones, the

update may result in localized disruption to traffic on ports associated

with the traffic isolation zone changes

Do you want to enable 'cfg_TI' configuration (yes, y, no, n): [no] y

zone config "cfg_TI" is in effect

Updating flash ...

3. Log in to the edge fabric 2 and set up the TI zone.

a)

Enter the fabricShow command to display the switches in the fabric. From the output, you
can determine the front and translate domains.

E2switch:admin> fabricshow

Switch ID Worldwide Name Enet IP Addr FC IP Addr Name

-------------------------------------------------------------------------

1: fffc01 50:00:51:e3:95:36:7e:09 0.0.0.0 0.0.0.0

"fcr_fd_1"

4: fffc04 50:00:51:e3:95:48:9f:a1 0.0.0.0 0.0.0.0

"fcr_xd_6_9"

9: fffc09 10:00:00:05:1e:40:f0:7d 10.32.72.9 0.0.0.0

>"E2switch"

The Fabric has 3 switches

b)

Enter the following commands to create and display a TI zone:

E2switch:admin> zone --create -t ti TI_Zone1 -p "9,2; 9,3; 9,6; 1,-1; 4,-1"

E2switch:admin> zone --show

Defined TI zone configuration:

TI Zone Name: TI_Zone1

Port List: 9,2; 9,3; 9,6; 1,-1; 4,-1

Status: Activated Failover: Enabled

c)

Enter the following commands to reactivate your current effective configuration and
enforce the TI zones.

E2switch:admin> cfgactvshow

Effective configuration:

cfg: cfg_TI

zone: lsan_t_i_TI_Zone1

10:00:00:00:00:00:02:00:00

10:00:00:00:00:00:03:00:00

10:00:00:00:00:00:08:00:00

E2switch:admin> cfgenable cfg_TI

You are about to enable a new zoning configuration.

This action will replace the old zoning configuration with the

current configuration selected.

If the update includes changes to one or more traffic isolation zones, the

update may result in localized disruption to traffic on ports associated

with the traffic isolation zone changes

Do you want to enable 'cfg_TI' configuration (yes, y, no, n): [no] y

zone config "cfg_TI" is in effect

Updating flash ...

4. Log in to the backbone fabric and set up the TI zone.

a)

Enter the following commands to create and display a TI zone:

BB_DCX_1:admin> zone --create -t ti TI_Zone1 -p "1,9; 1,1; 2,4; 2,7;

10:00:00:00:00:08:00:00; 10:00:00:00:00:02:00:00; 10:00:00:00:00:03:00:00"

BB_DCX_1:admin> zone --show

Defined TI zone configuration:

TI Zone Name: TI_Zone1

Port List: 1,9; 1,1; 2,4; 2,7; 10:00:00:00:00:08:00:00;

Traffic Isolation Zoning

372

Fabric OS Administrators Guide

53-1003130-01