Top talker monitors and fc-fc routing – Brocade Fabric OS Administrators Guide (Supporting Fabric OS v7.3.0) User Manual
Page 503
Top Talker monitors are not supported on the embedded platforms: Brocade 5410, 5424, 5450, 5460,
5470, and 5480.
Top Talker monitors and FC-FC routing
You can enable Top Talker monitors on a platform that is configured to be an FC router. Top Talker
monitors and FC routers are concurrently supported on the following platforms:
• Brocade 6505
• Brocade 6510
• Brocade 6520
• Brocade DCX 8510 Backbone family, with the following blades only: FC16-32, FC16-48
On all other platforms, you can have either Top Talker monitors or FC-FC routing, but not both.
Top Talker monitors are supported on an FC router in both backbone-to-edge and edge-to-edge
configurations.
Note the following restrictions:
• An E_Port-attached switch must be connected and merged with the backbone FC router before you
can enable Top Talker monitors on the FC router.
• Fabric mode Top Talker monitors do not support requests for domains (either front port domain or
xlate domain).
• Fabric mode Top Talker monitors do not monitor flows over EX_Ports.
For example, if a host is connected directly to an FC router and the target is on the edge switch (refer to
), no flows are monitored because none of the flows traverse an E_Port on the FC router.
, however, the flows across the E_Port on the FC router are monitored.
Top Talker monitors and FC-FC routing
Fabric OS Administrators Guide
503
53-1003130-01