You can display the complete results from either the responder or the initiator switch. If the initiator
switch is running Fabric OS v7.1.x or earlier, the responder displays only the local D_Port results, and
you must query the initiator to see the complete results.

The following example shows the D_Port results.

switch:admin> portdporttest --show 26

D-Port Information:

===================

Port: 26

Remote WWNN: 10:00:00:05:33:13:2f:b5

Remote port index: 42

Mode: Automatic

Start time: Wed Feb 2 01:41:43 2011

End time: Wed Feb 2 01:43:23 2011

Status: PASSED

================================================================================

Test Start time Result EST(secs) Comments

================================================================================

Electrical loopback 01:42:08 PASSED -- ----------

Optical loopback 01:42:16 PASSED -- ----------

Link traffic test 01:43:15 PASSED -- ----------

================================================================================

Roundtrip link latency: 1108 nano-seconds

Estimated cable distance: 20 meters

Buffers required: 1 (for 1024 byte frames at 16Gbps speed)

The following example shows the portdporttest --show output where the electrical and optical tests
pass but the link test fails.

switch:admin> portdporttest --show 26

D-Port Information:

===================

Port: 26

Remote WWNN: 10:00:00:05:33:13:2f:b5

Remote port index: 42

Mode: Automatic

Start time: Wed Feb 2 01:41:43 2011

End time: Wed Feb 2 01:43:23 2011

Status: PASSED

================================================================================

Test Start time Result EST(secs) Comments

================================================================================

Electrical loopback 01:42:08 PASSED -- ----------

Optical loopback 01:42:16 PASSED -- ----------

Link traffic test 01:43:15 PASSED -- ----------

================================================================================

Roundtrip link latency: 1108 nano-seconds

Estimated cable distance: 20 meters

Buffers required: 1 (for 1024 byte frames at 16Gbps speed)

Use the portDportTest --show all command to display the capabilities and test results of all the
D_Ports in a switch.

switch:admin> portdporttest --show all

Port State SFP Capabilities Test Result

=============================================

24 ONLINE E,O PASSED

26 ONLINE E,O FAILED

33 ONLINE E,O PASSED

Use the switchShow command to see D_Port information.

switch:admin> switchshow

switchName: switch_10

switchType: 109.1

switchState: Online

switchMode: Native

switchRole: Principal

switchDomain: 1

switchId: fffc01

switchWwn: 10:00:00:05:33:13:2f:b4

zoning: OFF

Diagnostic Port