Excluding a single port from bottleneck detection

The following example excludes only port 7 from bottleneck detection. Refer to

Disabling bottleneck detection on a switch

on page 404 for more information.

NOTE
Excluding the master port excludes the entire trunk, even if individual slave ports
are not excluded.

switch:admin> bottleneckmon --exclude 7

switch:admin> bottleneckmon --status

Bottleneck detection - Enabled

==============================

Switch-wide sub-second latency bottleneck criterion:

====================================================

Time threshold - 0.800

Severity threshold - 50.000

Switch-wide alerting parameters:

================================

Alerts - Yes

Latency threshold for alert - 0.200

Congestion threshold for alert - 0.700

Averaging time for alert - 200 seconds

Quiet time for alert - 150 seconds

Per-port overrides for alert parameters:

========================================

Port Alerts? LatencyThresh CongestionThresh Time (s) QTime (s)

=================================================================================

46 N -- -- -- --

47 L 0.750 -- 250 150

Excluded ports:

===============

Port

====

7

Re-including a port for bottleneck detection

The following example restores bottleneck detection for port 7. The “Excluded
ports” section is not displayed because there are no excluded ports.

switch:admin> bottleneckmon --include 7

switch:admin> bottleneckmon --status

Bottleneck detection - Enabled

==============================

Switch-wide sub-second latency bottleneck criterion:

====================================================

Time threshold - 0.800

Severity threshold - 50.000

Switch-wide alerting parameters:

================================

Alerts - Yes

Latency threshold for alert - 0.200

Congestion threshold for alert - 0.700

Averaging time for alert - 200 seconds

Quiet time for alert - 150 seconds

Per-port overrides for alert parameters:

========================================

Port Alerts? LatencyThresh CongestionThresh Time (s) QTime (s)

=================================================================================

46 N -- -- -- --

47 L 0.750 -- 250 150

Bottleneck Detection

Fabric OS Administrators Guide

403