Disabling d_port in static mode – Brocade Fabric OS Administrators Guide (Supporting Fabric OS v7.3.0) User Manual
Page 431

3. Repeat steps 1 and 2 for the corresponding port (in this example, Port 2) on Switch B.
switchB:admin> portdisable 2
switchB:admin> portcfgdport --enable 2
4. Enable Port 1 on Switch A by using the portEnable command.
switchA:admin> portenable 1
5. Enable Port 2 on Switch B by using the portEnable command.
switchB:admin> portenable 2
The basic test suite starts as soon as both ports are enabled.
6. While the test is running, enter the portDportTest --show command to view test results. The
following test is successful.
switch:admin> portdporttest --show 10/39
D-Port Information:
===================
Slot:10
Port:52
Remote WWNN:10:00:00:05:33:7a:0f:c8
Remote port index:16
Mode:Manual
No. of test frames:1 Million
Test frame size:1024 Bytes
FEC (enabled/option/active):Yes/No/No
CR (enabled/option/active):Yes/No/No
Start time:Mon May 19 16:14:28 2014
End time:Mon May 19 16:18:23 2014
Status:PASSED
================================================================================
Test Start timeResultEST(HH:MM:SS)Comments
================================================================================
Electrical loopback--------SKIPPED --------No SFP or chip support
Optical loopback --------SKIPPED --------No SFP or chip support
Link traffic test 16:14:39PASSED ------------------
================================================================================
Roundtrip link latency:982091 nano-seconds
Approximate cable distance:99893 meters (99.893 Km)
Buffers required:965 (for 2112 byte frames at 16Gbps speed)
7. To display a summary of the D_Port, use the portDportTest --show all command.
switch:admin> portdporttest --show all
Port State SFP Capabilities Test Result
==============================================
24 ONLINE E,O PASSED
26 ONLINE E,O PASSED
33 OFFLINE --- FAILED
8. Optional : To stop the test on both ends, use the portDportTest --stop command on both the ends.
After stopping the test, verify manually that the test has stopped on both ends. You can restart the
test on both ends using the portDportTest --start/restart command on any one of the ends. You do
not need to run the same command on both ends of a single connection.
Disabling D_Port in static mode
Use this procedure to disable the D_Port diagnostics session enabled in
Enabling D_Port in static mode
on page 430
1. Disable Port 1 on Switch A by using the portDisable command.
switchA:admin> portdisable 1
2. Disable the D_Port on Port 1 on Switch A by using portCfgDport --disable command .
switchA:admin> portcfgdport --disable 1
Disabling D_Port in static mode
Fabric OS Administrators Guide
431
53-1003130-01