beautypg.com

Brocade Fabric OS Administrators Guide (Supporting Fabric OS v7.3.0) User Manual

Page 550

background image

Authentication Type: None

DH Group: N/A

Hash Algorithm: N/A

Edge fabric's primary wwn: N/A

Edge fabric's version stamp: N/A

switch:admin_06> portshow 7/10

portName:

portHealth: OFFLINE

Authentication: None

EX_Port Mode: Enabled

Fabric ID: 30

Front Phantom: state = Not OK Pref Dom ID: 160

Fabric params: R_A_TOV: 0 E_D_TOV: 0 PID fmt: auto

Authentication Type: None

Hash Algorithm: N/A

DH Group: N/A

Edge fabric's primary wwn: N/A

Edge fabric's version stamp: N/A

portDisableReason: None

portCFlags: 0x1

portFlags: 0x1 PRESENT U_PORT EX_PORT

portType: 10.0

portState: 2 Offline

portPhys: 2 No_Module

portScn: 0

port generation number: 0

portId: 014a00

portIfId: 4372080f

portWwn: 20:4a:00:60:69:e2:03:86

portWwn of device(s) connected:

Distance: normal

portSpeed: N4Gbps

LE domain: 0

FC Fastwrite: ON

Interrupts: 0 Link_failure: 0 Frjt : 0

Unknown: 0 Loss_of_sync: 0 Fbsy : 0

Lli: 0 Loss_of_sig: 2

Proc_rqrd: 0 Protocol_err: 0

Timed_out: 0 Invalid_word: 0

Rx_flushed: 0 Invalid_crc: 0

Tx_unavail: 0 Delim_err: 0

Free_buffer: 0 Address_err: 0

Overrun: 0 Lr_in: 0

Suspended: 0 Lr_out: 0

Parity_err: 0 Ols_in: 0

2_parity_err: 0 Ols_out: 0

CMI_bus_err: 0

Port part of other ADs: No

10.Enter the switchShow command to verify the EX_Port (or VEX_Port), edge fabric ID, and name of

the edge fabric switch (containing the E_Port or VE_Port) are correct.

11.Enter the fcrFabricShow command to view any edge fabric switch names and ensure links are

working as expected.

NOTE
The fcrFabricShow command displays the static IPv6 addresses for each FC router and each
edge fabric switch connected to the EX_Ports.

switch:admin> fcrfabricshow

FCR WWN: 10:00:00:05:1e:13:59:00, Dom ID: 2, Info: 10.32.156.52 1080::8:800:200C:

1234/64,"Spirit-2"

"fcr_5300"

EX_Port FID Neighbor Switch Info (WWN, enet IP, name)

---------------------------------------------------------------

7 10 10:00:00:05:1e:34:11:e5 10.32.156.33 "5300" 1080::8:8FF:FE0C:417A/64

4 116 10:00:00:05:1e:37:00:44 10.32.156.34 "5300"

FCR WWN: 10:00:00:05:1e:12:e0:00, Dom ID: 100, Info:10.32.156.50 1080::8:60F:FE0C:

456A/64

"fcr_5300"

EX_Port FID Neighbor Switch Info (WWN, enet IP, name)

------------------------------------------------------------------------

4 95 10:00:00:05:1e:37:00:45 10.32.156.31 "5300"

FCR WWN: 10:00:00:05:1e:12:e0:00, Dom ID: 100, Info: 10.32.156.50, "fcr_Brocade

Using FC-FC Routing to Connect Fabrics

550

Fabric OS Administrators Guide

53-1003130-01