Total FC ports, ports per port group, and unreserved buffer credits per port group
(Continued)

TABLE 17

Switch/blade model

Total FC ports (per
switch/blade)

User port group size Unreserved buffer credits per

port group

FC16-32

32

16

5408

FC16-48

48

24

4960

FC16-64

64

32

4288

FS8-18

16

8

1604

FX8-24

12

12

1060

For the FC8-x port blades, the first number in the "Unreserved buffer credits per port group" column
designates the number of unreserved buffers per port group without buffer optimized mode; the
second number designates the unreserved buffers with buffer optimized mode enabled on the slot.
Use the bufOpMode command to display or change the buffer optimized mode.

Maximum configurable distances for Extended Fabrics

The following table shows the maximum supported extended distances (in kilometers) that can be
configured for one port on a specific switch or blade at different speeds.

Formulae:

The remaining buffers = (Total FE Ports * 8) + (Total BE/BI Ports * Buffers for BE/BI Port) + EMB
Buffers + SAB Buffers

Long distance Calculation: Buffers = distance * speed * 0.5

Distance = (Buffers * 2) / speed

Configurable distances for Extended Fabrics

TABLE 18

Maximum distances (km) that can be configured (assuming a 2112-byte frame size)

Switch/blade model

2 Gbps

4 Gbps

8 Gbps

10 Gbps

16 Gbps

300

486

243

121

N/A

N/A

5100

1694

847

423

N/A

N/A

5300

294

147

73

N/A

N/A

5410

582

291

145.5

N/A

N/A

5424

486

243

121.5

N/A

N/A

5431

550

275

137.5

N/A

N/A

5432

486

243

121.5

N/A

N/A

5450

470

235

117.5

N/A

N/A

Maximum configurable distances for Extended Fabrics

126

Fabric OS Administrators Guide

53-1003130-01