Yokogawa Data Acquisition with PID Control CX2000 User Manual
Page 277

App-18
IM 04L31A01-17E
Parameters Related to Loop 6
43501-43519
43601-43612
43625-43628
43631-43642
43655-43658
43661-43672
43685-43688
43691-43702
43715-43718
43721-43732
43745-43748
43751-43762
43775-43778
43781-43792
43805-43808
43811-43822
43835-43838
Parameter per
Loop
PID parameter of
PID number 1 of
loop 6
Control alarm
value of PID
number 1 of loop 6
PID parameter of
PID number 2 of
loop 6
Control alarm
value of PID
number 2 of loop 6
PID parameter of
PID number 3 of
loop 6
Control alarm
value of PID
number 3 of loop 6
PID parameter of
PID number 4 of
loop 6
Control alarm
value of PID
number 4 of loop 6
PID parameter of
PID number 5 of
loop 6
Control alarm
value of PID
number 5 of loop 6
PID parameter of
PID number 6 of
loop 6
Control alarm
value of PID
number 6 of loop 6
PID parameter of
PID number 7 of
loop 6
Control alarm
value of PID
number 7 of loop 6
PID parameter of
PID number 8 of
loop 6
Control alarm
value of PID
number 8 of loop 6
Same as the parameters for loop
1
*2
Same as the PID parameters of
PID number 1 of loop 1
Same as the control alarm values
of PID number 1 of loop 1
Same as the PID parameters of
PID number 1 of loop 1
Same as the control alarm values
of PID number 1 of loop 1
Same as the PID parameters of
PID number 1 of loop 1
Same as the control alarm values
of PID number 1 of loop 1
Same as the PID parameters of
PID number 1 of loop 1
Same as the control alarm values
of PID number 1 of loop 1
Same as the PID parameters of
PID number 1 of loop 1
Same as the control alarm values
of PID number 1 of loop 1
Same as the PID parameters of
PID number 1 of loop 1
Same as the control alarm values
of PID number 1 of loop 1
Same as the PID parameters of
PID number 1 of loop 1
Same as the control alarm values
of PID number 1 of loop 1
Same as the PID parameters of
PID number 1 of loop 1
Same as the control alarm values
of PID number 1 of loop 1
Same as the range for the parameters for
loop 1
Same as the range for the PID parameters
of PID number 1 of loop 1
Same as the range for the control alarm
values of PID number 1 of loop 1
Same as the range for the PID parameters
of PID number 1 of loop 1
Same as the range for the control alarm
values of PID number 1 of loop 1
Same as the range for the PID parameters
of PID number 1 of loop 1
Same as the range for the control alarm
values of PID number 1 of loop 1
Same as the range for the PID parameters
of PID number 1 of loop 1
Same as the range for the control alarm
values of PID number 1 of loop 1
Same as the range for the PID parameters
of PID number 1 of loop 1
Same as the range for the control alarm
values of PID number 1 of loop 1
Same as the range for the PID parameters
of PID number 1 of loop 1
Same as the range for the control alarm
values of PID number 1 of loop 1
Same as the range for the PID parameters
of PID number 1 of loop 1
Same as the range for the control alarm
values of PID number 1 of loop 1
Same as the range for the PID parameters
of PID number 1 of loop 1
Same as the range for the control alarm
values of PID number 1 of loop 1
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Modbus
Register
Number
Description
Register Type
Value
Read/
Write
*2 Loops 5 and 6 do not have Remote, bias setting against PV range, filter setting, and remote/local
switching.
Appendix 6 Register Assignments