2 a list of commands, Setting commands (control) – Yokogawa Data Acquisition with PID Control CX2000 User Manual
Page 133

6-4
IM 04L31A01-17E
6.2
A List of Commands
Setting Commands (Control)
Command Command Function
Execution mode
ADMINISTRATOR
USER Page
Type
Name
Control Input Range
CR
Sets the control range
Operation mode
Yes
No
6-15
MP
Control range settings
Operation mode
Yes
No
6-16
(used during control computations)
MB
Bias
Operation mode
Yes
No
6-16
MF
Filter
Operation mode
Yes
No
6-17
RS
Set the ratio
Operation mode
Yes
No
6-17
Control Alarm
AT
Sets the control alarm
Operation mode
Yes
No
6-17
AV
Sets the control alarm value
Operation mode
Yes
No
6-17
Operation-related Parameters
HS
Sets the suppressing function
Operation mode
Yes
No
6-17
HT
Sets the ramp-rate-time unit
Operation mode
Yes
No
6-17
HH
Sets the SP ramp-up-rate
Operation mode
Yes
No
6-18
HL
Sets the SP ramp-down-rate
Operation mode
Yes
No
6-18
HM
Sets the loop tag and tag comment
Operation mode
Yes
No
6-18
GC
Zone PID setting 1 (reference points)
Operation mode
Yes
No
6-18
GD
Zone PID setting 2 (switching hysteresis)
Operation mode
Yes
No
6-18
HW
Zone PID setting 3 (reference deviation)
Operation mode
Yes
No
6-18
PID Parameters
GO
Sets the target setpoint
Operation mode
Yes
No
6-18
HP
Sets the proportional band
Operation mode
Yes
No
6-18
HI
Sets the integral time
Operation mode
Yes
No
6-18
HD
Sets the derivative time
Operation mode
Yes
No
6-19
HO
Sets control-related parameters
Operation mode
Yes
No
6-19
Control Group Settings
FG
Sets the control group name
Operation mode
Yes
No
6-19
GG
Sets the control group
Operation mode
Yes
No
6-19
Ten-segment lIinearizer Input/Output
HA
Sets the ten-segment linearizer mode
Operation mode
Yes
No
6-20
HE
Sets the ten-segment linearizer segment
Operation mode
Yes
No
6-20
Pattern Initial Setting
PB
Sets initial patterns
Operation mode
Yes
No
6-20
PI
Operating loop settings
Operation mode
Yes
No
6-20
Wait Action Setting
PZ
Sets the wait zone
Operation mode
Yes
No
6-21
PW
Sets the wait time
Operation mode
Yes
No
6-21
Program Initial Setting
PO
Sets the start setpoint
Operation mode
Yes
No
6-21
PQ
Sets the start code
Operation mode
Yes
No
6-21
Program Operation Parameters
PD
Sets the ramp/soak select
Operation mode
Yes
No
6-21
PM
Sets the final target setpoint
Operation mode
Yes
No
6-21
PT
Sets the segment time
Operation mode
Yes
No
6-21
PU
Sets the ramp-rate time unit/ramp
Operation mode
Yes
No
6-21
PG
Segment PID group number
Operation mode
Yes
No
6-21
PJ
Sets the segment shifting action and wait
Operation mode
Yes
No
6-21
Yes: Command usable
No: Command not usable