Basic setting commands (control), Basic setting commands (control) -9 – Yokogawa Data Acquisition with PID Control CX2000 User Manual
Page 138

6-9
IM 04L31A01-17E
Command
6
Command Function
Execution mode
ADMINISTRATOR
USER Page
Name
YO
Loads setup data
Basic setting mode
Yes
No
6-46
YC
Clears the measured/computed data,
Basic setting mode
Yes
No
6-46
initializes setup data
YT
Sets the FTP transfer timing
Basic setting mode
Yes
No
6-46
YG
Sets whether to use the Web server function Basic setting mode
Yes
No
6-46
YL
Sets the operation of the Modbus master
Basic setting mode
Yes
No
6-46
function
YM
Sets the command of the Modbus master
Basic setting mode
Yes
No
6-46
function
YU
Sets the contents to be sent via e-mail
Basic setting mode
Yes
No
6-47
YV
Sets the e-mail recipient address
Basic setting mode
Yes
No
6-48
YW
Sets the e-mail sender address
Basic setting mode
Yes
No
6-48
YX
Sets the e-mail SMTP server name
Basic setting mode
Yes
No
6-48
ML
Sets the communication buffer recovery
Basic setting mode
Yes
No
6-48
processing
MM
Sets the modbus mouse/temperature meter
Basic setting mode
Yes
No
6-48
communication automatic recovery
Yes: Command usable
No: Command not usable
Basic Setting Commands (Control)
Command Command Function
Execution mode
ADMINISTRATOR
USER Page
Type
Name
Control Action, Input Setting
GB
Sets the PID group number
Basic setting mode
Yes
No
6-49
GI
Sets the control period
Basic setting mode
Yes
No
6-49
HX
Sets control action parameters
Basic setting mode
Yes
No
6-49
PY
Sets 6/4loop select (CX2000 only)
Basic setting mode
Yes
No
6-49
HQ
Turns Off/On auto tuning
Basic setting mode
Yes
No
6-49
PC
Sets the control mode
Basic setting mode
Yes
No
6-49
PP
Turns Off/On the program control
Basic setting mode
Yes
No
6-49
GM
Sets the PID control mode
Basic setting mode
Yes
No
6-49
HB
Sets the burn out
Basic setting mode
Yes
No
6-49
MK
Sets the burn out
Basic setting mode
Yes
No
6-50
(when PV/SP computation is ON)
HR
Sets the RJC
Basic setting mode
Yes
No
6-50
MJ
Sets the RJC
Basic setting mode
Yes
No
6-50
(when PV/SP computation is ON)
Contact Input Registration/AUX
GT
Registers contact inputs
Basic setting mode
Yes
No
6-50
GS
Sets remote input
Basic setting mode
Yes
No
6-51
HG
Sets the alarm mode
Basic setting mode
Yes
No
6-51
HY
Sets the SP number selection source
Basic setting mode
Yes
No
6-51
MY
Turns Off/On PV/SP computation
Basic setting mode
Yes
No
6-51
MZ
Sets the CLOG error
Basic setting mode
Yes
No
6-51
Output Processing
GF
Sets the output processing
Basic setting mode
Yes
No
6-51
Relay
GR
Sets relay parameters
Basic setting mode
Yes
No
6-51
GE
Sets relay action
Basic setting mode
Yes
No
6-51
Tuning Setting
GU
Turns Off/On the tuning item
Basic setting mode
Yes
No
6-52
6.2 A List of Commands