Event data, Manual sampled data, Report data (hourly, daily, weekly, and monthly) – Yokogawa Data Acquisition with PID Control CX2000 User Manual
Page 222

7-30
IM 04L31A01-17E
Event Data
• The MI command is used to output the FIFO data.
• The ID number of the output format is “12.” See “Identifier” on page 7-3.
Header
Block 1
. . .
Block n
BINARY data
(The BINARY data section
on the “Conceptual diagram”
on page 7-2.)
Header
Same as the “Header” for the display data.
Block
2 bytes
4 bytes
Computed data
. . .
. . .
Measured data
. . .
. . .
Control data
. . .
. . .
Special Data Values
The measured/computed/control data take on the following values under special
conditions.
Special Data Value Type
Measured/Control Data
Computed Data
+ Over
7FFFH
7FFF7FFFH
– Over
8001H
80018001H
Skip
8002H
80028002H
Error
8004H
80048004H
Undefined
8005H
80058005H
Note
The measured/computed/control data is output according to the byte order specified with the BO
command.
Manual Sampled Data
• The ME or MO command is used to output the data.
• The ID number of the output format is “4.” See “Identifier” on page 7-3.
• For a description of the data format, see the user’s manual IM 04L31A01-01E or IM
04L31A01-03E
.
Report Data (Hourly, Daily, Weekly, and Monthly)
• The ME or MO command is used to output the data.
• The ID number of the output format is “5” for the hourly data, “6” for the daily data, “7”
for the weekly data, and “8” for the monthly data. See “Identifier” on page 7-3.
• For a description of the data format, see the user’s manual IM 04L31A01-01E or IM
04L31A01-03E
.
7.3 Output Format of BINARY Data