Output commands (control), Output commands (control) -11 – Yokogawa Data Acquisition with PID Control CX2000 User Manual
Page 140

6-11
IM 04L31A01-17E
Command
6
Command Command Function
Execution mode
ADMINISTRATOR
USER Page
Type
Name
Setup, Measurement, and computation Data Output
FC
Outputs the screen image data
All modes
Yes
Yes
6-55
FE
Outputs the setup data
All modes
Yes
Yes
6-55
FD
Outputs the newest measured/computed/
Operation mode
Yes
Yes
6-56
control data
FF
Outputs FIFO data
Operation mode
Yes
Yes
6-56
FL
Outputs log, alarm summary, and message
All modes
Yes
Yes
6-56
summary
FS
Outputs alarm types and setting value for
All modes
Yes
Yes
6-57
measurement/computation/control channel
FT
Outputs max/min/decimal point of span for
All modes
Yes
Yes
6-57
measurement/computation/control channel
IS
Outputs status information
All modes
Yes
Yes
6-57
FU
Outputs the user level
All modes
Yes
Yes
6-57
ME
Outputs the data stored on the external
Operation mode
Yes
No
6-57
storage medium (usable through either
Ethernet or serial communications)
MI
Outputs display data and event data in the
Operation mode
Yes
No
6-57
internal memory (usable through either
Ethernet or serial communications)
MO
Outputs TLOG data, manual sample data,
Operation mode
Yes
No
6-58
and report data in the internal memory
(usable through either Ethernet or serial communications)
RS-422/485 Dedicated Commands
ESC O
Opens the device
All modes
Yes
Yes
6-59
ESC C
Closes the device
All modes
Yes
Yes
6-59
Yes: Command usable
No: Command not usable
Output Commands (Control)
Command Command Function
Execution mode
ADMINISTRATOR
USER Page
Type
Name
output commands
FP
Outputs the SP number and PID number.
All modes
Yes
Yes
6-59
FM
Outputs the control mode.
All modes
Yes
Yes
6-59
FH
Outputs the program operation mode.
All modes
Yes
Yes
6-59
FJ
Outputs program pattern information that
All modes
Yes
Yes
6-60
is currently in execution.
FK
Outputs PV event/time event information.
All modes
Yes
Yes
6-60
FN
Outputs the DI/DO data and internal
All modes
Yes
Yes
6-60
switches status.
FO
Outputs the status (active/inactive) of DIO
All modes
Yes
Yes
6-60
operation monitoring function setting and
operation mode (automatic/manual).
FW
Outputs the information on pattern numbers, All modes
Yes
Yes
6-60
operation status, and assigned loops.
DQ
Outputs the SP number and PID number of
All modes
Yes
Yes
6-60
external loops.
DR
Outputs the control mode of external loops.
All modes
Yes
Yes
6-60
FV
Outputs the status of the program control
All modes
Yes
Yes
6-61
end signal
Yes: Command usable
No: Command not usable
6.2 A List of Commands