Sp number and pid number, Sp number and pid number -10 – Yokogawa Data Acquisition with PID Control CX2000 User Manual
Page 202

7-10
IM 04L31A01-17E
uuuuuu
Unit information (6 characters, left-justified)
mV____: mV
V_____: V
^C____: °C
xxxxxx: (User-defined character string)
f
Sign (+, -)
ddddd
Mantissa
(00000 to 99999, 5 digits)
• 8 digits for computed data.
• For abnormal data (data status is E) or data of which the mantissa
or the exponent exceeds the range (data status is O), the mantissa
is set to 99999 (99999999 for computed data).
pp
Exponent (00 to 04)
_
Space
Example
EA
DATE 99/02/23
TIME 19:56:32.500
N 001h mV +12345E-03
N 002 mV -67890E-01
S 003
EN
Note
• Data for non-existing channels is not output (not even the channel number).
• For channels set to skip, output values from alarm status to exponent are spaces.
SP Number and PID Number
• Output data using an FP command for internal loops, or a DQ command for external
loops.
• The SP number and PID number that are currently used by the selected loop are
output.
Syntax
The SP number is output followed by the PID number.
EA
CRLF
SPNO_x
CRLF
PIDNO_y
CRLF
EN
CRLF
x
SP number (1 to 8)
y
PID number (1 to 8)
_
Space
Example
EA
SPNO 1
PIDNO 2
EN
7.2 Output Format of ASCII Data