• Data Size per Sample
Display Data

(Number of I/O channels × 12 bytes) + (number of math channels × 12 bytes) + (number

of communication channels × 12 bytes) + 16 bytes (time data)

Event Data

(Number of I/O channels × 6 bytes) + (number of math channels × 6 bytes) + (number of

communication channels × 6 bytes) + 16 bytes (time data)

• Sampled Data Size per File
Display Data

Data size per sample ×

saving interval/sampling interval

The sampling interval is determined by dividing the

trend interval (in seconds) by 30 (50

if the trend interval is 5 or 10 s).

Example 2: When recording the display data for 30 I/O channels, 10 math channels, and

50 communication channels at a

trend interval of 30 min/div (the sampling interval of

display data is 60 s), and a

saving interval of 1 day (24 h)

(30 × 12 bytes + 10 × 12 bytes + 50 × 12 bytes + 16 bytes) × 24 h Ч 60 Ч 60/60 sec

= 1,096 bytes × 24 h Ч 60 Ч 60/60 sec

= 1,578,240 bytes

Event Data

Data size per sample×

data length/Recording interval

Example 3: When recording event data for 30 I/O channels, 10 math channels, 50

communication channels at a

Recording interval of 1 s and a data length of 2 h

(30 × 6 bytes + 10 × 6 bytes + 50 × 6 bytes + 16 bytes) × 2 h Ч 60 Ч 60/1 s

= 556 bytes × 2 h Ч 60 Ч 60/1 s

= 4,003,200 bytes

Size per File

The size per file is the sum of the size of information other than the sampled data and the

size of the sampled data.

Display Data

Example 4: When recording under the conditions of examples 1 and 2

From examples 1 and 2, we obtain 37,336 + 1,578,240 = 1,615,576 bytes = 1.541 MB

Event Data

Example 5: When recording under the conditions of examples 1 and 3

From examples 1 and 3, we obtain 37,336 + 4,003,200 = 4,040,536 bytes = 3.853 MB