Configuring the SMTP Client Function (E-mail transmission)

Item

Reference

Setting the user authentication method

→page 1-127

Setting the SMTP server

Setting the POP3 server

Setting the e-mail transmission conditions (recipients, subject, header, cause, etc.) →page 1-128

Configuring the SNTP Client Function (Time synchronization via

communication)

Item

Reference

Configuring the SNTP server

→page 1-130

Setting the query operation (interval, timeout, time adjust on start action)

Configuring the Modbus Client Function (External device connection via

Modbus protocol; /MC option)

Item

Reference

Enabling the Modbus client function and configuring basic settings (communication

interval, recovery action, keep connection)

→page 1-132

Configuring the destination server

Setting the commands to transmit (type, data type, register, etc.)

Limiting the Connection to the Modbus Server (GX/GP)

Item

Reference

Limiting the connection to the Modbus server (GX/GP)

→page 1-136

Configuring the Operation of the Server Functions

Item

Reference

Setting the operation of the server functions (keep alive, timeout, FTP server output

directory format, Modbus server delay response)

→page 1-135

Setting the Server Functions to Use

Item

Reference

Setting the server functions to use (FTP, HTTP, SNTP, MODBUS, GENE)

→page 1-136

Configuring the Serial Communication Function (/C2 and /C3 options) (Setting

menu: Communication (serial) settings)

Configuring Basic Settings

Item

Reference

Configuring the serial communication function (normal, Modbus master, Modbus

slave)

→page 1-138

Setting communication conditions (baud rate, parity, handshake, etc.)

Configuring the Modbus Master Function

Item

Reference

Configuring the Modbus master function (communication interval, communication

timeout, gap between messages, recovery action)

→page 1-139

Setting the Modbus master transmission commands (type, data type, register, etc.) →page 1-140

Setting Communication Channels (/MC option) (Setting menu: Communication

channel settings)

Item

Reference

Setting communication channels (decimal place, span (upper, lower), unit)

→page 1-116

Replacing values with preset values when communication data is not updated for a

specified time period (watchdog timer function)

Setting Alarms

Item

Reference

Setting alarms (type, value, hysteresis, logging, output, alarm delay)

→page 1-118