beautypg.com

Watlow Series D8 User Manual

Page 228

background image

Index

Series D8 User’s Guide

210

Watlow Anafaze

Doc. 0600-3120-2000

S

safety

external safety devices 8

output status on power up 9

symbols and signal words in this manual 2

Save Setup As Job 76, 125

scaling resistors

for current inputs 30, 173

for RTD inputs 30, 175

for thermistor inputs 175

for voltage inputs 30, 174

installing 172–176

scan 50, 51, 60

scanner 49, 50, 51, 52, 53, 54, 55, 57

SCSI cable 7, 8

clearance 14, 181

installing 25

Sensor Fail Cool Output 69, 142

and failed sensor alarm 93

mode override 127

reversed thermocouple detection 133

thermocouple short alarm 129

Sensor Fail Heat Output 69, 142

and failed sensor alarm 93

mode override 127

reversed thermocouple detection 133

thermocouple short alarm 129

sensor inputs

calibration offset 132

engineering units 132

failed sensor alarms 160

filte 135

specification 185

troubleshooting 166

wiring 27–30

Serial DAC

agency compliance 194

clock input 194

configuring output 176

configuring the controller outpu 139

dimensions 19, 193

environment 193

input specification 194

jumper positions 176

mounting 19

output specification 195

process variable retransmit 98

setup parameters 140

specification 193–195

weight 193

wiring 39–40

services 57, 61

Set Attribute Single 57

Set Point 68

set point

changing 84

on loop display 80

remote analog set point 107–109

using cascade control to set 100–104

using differential control to set 106–107

using ratio control to set 104–109

Set Points 64

setting up a process input 88

shutdown devices 8

solid-state relays

5 Vdc power from controller 188

distributed zero crossing 119

troubleshooting controller connections 168

specification 179–195

controller inputs 185–187

controller outputs 187–188

Dual DAC 191–192

power supply 189–190

Serial DAC 193–195

TB50 181–184

spread, see hysteresis

system alarms

behavior of 160

messages 82, 83

troubleshooting 163–166

T

T/C open alarm message 82

T/C reversed alarm message 82

T/C shorted alarm message 82

TB18

alarm outputs 33, 34

connections 36

CPU watchdog timer output 34

digital output wiring 32

testing after installation 26

troubleshooting 168

TB50 183

alarm outputs 33, 34

connections 25, 37

CPU watchdog timer output 34

digital inputs 35

digital output wiring 32

dimensions 181–184

mounting on DIN rail 16

mounting with standoffs 17

specification 181–184

technical description 8

terminal specification 182

testing after installation 26

troubleshooting 168

weight 181

temperature

incorrect on display 161, 166

operating 179, 189, 191, 193

storage 179, 189, 191, 193

temperature scale 132

terminal specification

TB50 182

Test D/O parameter 153

testing

TB18 after installation 26

TB50 after installation 26

see also troubleshooting

The 191

thermistor inputs, scaling resistors for 175

Thermocouple Short Alarm 76, 94, 129

thermocouples

accuracy 186

alarm messages 82

calibration offset 132

ground loops 29

manual mode if break occurs 142

polarity checking 133

range 186

resolution 186

reversed detection 133

troubleshooting 167

types supported 131

wiring 29

thermoforming example 107

tie wraps 31

time proportioning 139

cycle time 140

description 118

TO alarm code 82

torque, see terminal specification