beautypg.com

Watlow Series D8 User Manual

Page 225

background image

Series D8 User’s Guide

Index

Doc. 0600-3120-2000

Watlow Anafaze

207

ESD, see electrostatic discharge

Exception Status Byte 45, 53

explicit messages 53, 55–58, 66, 68

external bridge circuit 30

external safety devices 8

F

Fahrenheit 132

failed sensor alarms

behavior of 160

codes 81–82

messages 81–82

output power if sensor alarm occurs 142

restoring automatic control after sensor repair 95, 138

RTD alarm 94

setting up 93–95

thermocouple open 94, 142

thermocouple reversed 94, 133

thermocouple short 94

filte

output 120, 137

sensor input 135

firm are

checksum 131

version 131

flash memor , replacing 170–171

front panel 7

display, see display

keypad, see keypad

G

gain, see proportional band

Get Attribute Single 57

Global object 125–129, 152, 153

Global Setup menu 125–131

ground loops 22–23

isolation 31

paths 22

and thermocouples 29

troubleshooting 167

grounding, troubleshooting 167

Group 2 Only Slave 60

H

H/W failure: Ambient 83, 165

H/W failure: Gain 83, 164

H/W failure: Offset 83, 164

HD alarm code 82

Heat Action 69, 141

Heat Cycle Time 69, 140

Heat Derivative 70, 137

Heat Filter 70, 137

Heat Integral 70, 137

Heat Manual Reset 70, 137

heat message on loop display 80

Heat Output 69, 85

Heat Output Curve 69, 143

Heat Output Retransmit 73, 148

Heat Output Type 69, 139

heat output, see control outputs

Heat Outputs 64

Heat Power Limit 69, 141

Heat Power Limit Time 69, 141

Heat Proportional Band 70, 136

Heat Retransmit High Process Variable 73, 148

Heat Retransmit Low Process Variable 73, 148

Heat SDAC High Signal 69, 140

Heat SDAC Low Signal 69, 140

Heat SDAC Signal 69, 140

Heat/Cool Output Action for Watchdog Inactivity Fault 69

high deviation alarm, see process alarms

High Deviation Function 145

High Deviation Output 72, 145

High Deviation Value 71, 97, 145

humidity specificatio

controller 179

Dual DAC 191

power supply 189

Serial DAC 193

HW Ambient Status 76

HW Gain Status 76

HW Offset Status 76

Hysteresis 71, 138

hysteresis

alarm 96

control 138

I

I/O Tests menu 151–153

Identity Object 61

input data 45, 51, 52, 53, 64, 65

Input Filter 68

description 135

setting before autotuning 93

Input High Signal 68, 134

Input Low Signal 68, 135

Input Menu 131–135

Input Object 67

input power, see power supply

Input Range High 68, 134

Input Range Low 68, 135

input scaling 88–91

Input Type 68

Input Units 68, 132

inputs

analog, see sensor inputs

current, see current inputs

digital, see digital inputs

filte 135

RTD, see RTD

scaling 88–91

scaling parameters 88–91, 134, 135

scaling resistors 172–176

sensor inputs wiring 27–30

sensor, see sensor inputs

setup parameters 131–135

specification 185–187

thermocouple, see thermocouples

voltage, see voltage inputs

installation 11–44

alarm wiring 33

clearance 14, 181

control output wiring 33

controller 13–15

digital output wiring 31–32

Dual DAC 19

environment 12

ground loops, see ground loops

location 12

noise suppression, see noise

overview 11

panel hole dimensions 14

panel thickness 14

power supply 18, 23–25

sensor input wiring 27–30

Serial DAC 19

system components 12

TB50 16–17, 25

testing 26, 27

tie-wrapping cables 31