Deferred image transport, Table 140: advanced register: deferred, Image transport – ALLIED Vision Technologies Stingray F-504 User Manual
Page 312

Configuration of the camera
STINGRAY Technical Manual V4.4.4
310
Deferred image transport
Using this register, the sequence of recording and the transfer of the images
can be paused. Setting HoldImg prevents transfer of the image. The images
are stored in ImageFIFO.
The images indicated by NumOfImages are sent by setting the SendImage
bit.
When FastCapture is set (in Format_7 only), images are recorded at the high-
est possible frame rate.
Register
Name
Field
Bit
Description
0xF1000260
DEFERRED_TRANS
Presence_Inq
[0]
Indicates presence of this
feature (read only)
---
[1..4]
Reserved
SendImage
[5]
Send NumOfImages now
(auto reset)
HoldImg
[6]
Enable/Disable deferred
transport mode
FastCapture
[7]
Enable/disable fast capture
mode
---
[8..15]
Reserved
FiFoSize
[16..23] Size of FIFO in number of
images (read only)
NumOfImages
[24..31] Write: Number of images to
send
Read: Number of images in
buffer
Table 140: Advanced register: Deferred image transport