beautypg.com

Tektronix MTG100 User Manual

Page 98

background image

Hierarchy Display

MTG100 & MTG300 MPEG Generator User Manual

3Ć39

Random Error Stress Dialog Box. When you select the Random Error... command
from the Bezel menu on your MTG300 MPEG generator, the Random Error
Stress dialog box appears as shown in Figure 3-15. Use the rotary knob or
hexadecimal keypad to set the interval. Press the Apply bezel button to apply the
random error stress to the transport stream output.

Table 3-37 describes the Random Error Stress dialog box parameters and Table
3-38 describes the Bezel menu commands associated with the dialog box.

Figure 3Ć15: Random Error Stress dialog box

Table 3Ć37: Random Error Stress dialog box parameters

Parameter

Description

Interval

Sets the interval that the random error is inserted into the transport stream

output. You canset the value from 2 to 4294967295 byte in1 byte steps.

Error rate

Shows the error rate (error/sec).

Table 3Ć38: Bezel menu commands for the Error Rate Stress dialog box

Command

Description

Apply

Enables the insertion of the random error.

Undo Stress

Disables the insertion of the random error.

Exit

Cancels any setting changes and closes the dialog box.

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com