3Ć49
PMT IntervalDialog Box. When you select the Interval... command from the Bezel
menu on your MTG300 MPEG generator, the PMT Interval dialog box appears
as shown in Figure 3-18.
The PMT interval parameter sets the time between occurrences of the PMT in
the transport stream. Use the rotary knob or hexadecimal keypad to change the
interval. You can set the value from 50 ms to 30000 ms in 1 ms steps.
Table 3-52 describes the Bezel menu commands associated with the dialog box.
Figure 3Ć18: PMT Intervaldialog box
Table 3Ć52: Bezelmenu commands for the PMT Intervaldialog box
Command
Description
Undo Stress
Returns the PMT interval to the default value and closes the dialog box.
Keep Stress
Enables the PMT interval. When youchange the PMT interval, the new
interval value is displayed in orange after the PMT icon.
Table 3-53 describes the text information and Table 3-54 describes the Bezel
menu commands for the Program Clock Reference (PCR) icon.
Table 3Ć53: PCR icon text descriptions
Parameter
Description
PID
Shows the PID value of the PCR.
Interval
Shows the period of the PCR.
Program Clock Reference
(PCR) Icon