Pull-down Menus

MTG100 & MTG300 MPEG Generator User Manual

3Ć13

Table 3Ć12: Insertion Setup dialog box parameters

Parameter

Description

Filename

Shows the directory path and name of the section or transport stream file

selected in the Select Insert File dialog box. The default directory path is

/main/usr/insert.

Table ID

Shows the table_id value of the table corresponding to the section file. The

value is automatically defined by the selected file.
This parameter appears only when the selected insertion file is a section file.

File Size

Shows the size of the selected section or transport stream file.

Time System

Shows the reference time used by the Start Time parameter to start the file

insertion: Relative, TDT, TOT, or STT. Relative is displayed when a TDT,

TOT, or STT is not present in the transport stream. TDT, TOT, or STT is

displayed when a TDT, TOT, or STT is present in the transport stream.

PID

When the insertion file is a section file, this parameter sets the PID value

when the section file is packetized. You can set the value from 0 to 8191

(0x0000 to 0x1FFF).
When the insertion file is a transport stream, this parameter sets the PID

value of the transport stream packet (file). You can set the value from

0 to 8191 (0x0000 to 0x1FFF).
When you access the Insertion Setup dialog box from an INS_SI or INS_TS

icon in the hierarchy display, this parameter is automatically set by the

stream item and cannot be changed.

Section

Sets the mode for how section data will be contained in the transport stream

packets. You can select SINGLE or MULTI. Refer to Section Modes on

page 3Ć83 for more information.
This parameter appears only when the selected insertion file is a section file.

Start Time

Sets the time when file insertion is started. You can set the time value from

00:00:00:000 to 24:59:59:999Ă(hoursĂ:ĂminutesĂ:ĂsecondsĂ:Ămilliseconds).

How this Start Time parameter works depends on the setting of the Time

System parameter in this dialog box.
When the Time System parameter is Relative, file insertion starts when the

period of time set in this Start Time parameter has elapsed after the start of

the transport stream output.
When the Time System parameter is TDT, TOT, or STT, file insertion starts

when the time described in the TDT, TOT, or STT of the transport stream

corresponds to the time set in this Start Time parameter. For userĆinserted

TDTs, TOTs, and STTs, the TDT Item, TOT item, and STT Item dialog

boxes contain a parameter to set the start time. When the start time setting

in this dialog box matches the start time setting in the TDT Item, TOT item,

or STT Item dialog box, file insertion is started.

Continuous

Sets the duration for the file insertion. When you select TIME, you can set

the time value from 00:00:00:000 to 24:59:59:999Ă(hoursĂ:ĂminutesĂ:ĂseĆ

condsĂ:Ămilliseconds). When you select INFINITE or set the time value to

00:00:00:000, the file insertion duration is set toĂinfinite.