background image

Hierarchy Display

MTG100 & MTG300 MPEG Generator User Manual

3Ć51

PCR Stress Dialog Box. When you select the Stress PCR... command from the
Bezel menu on your MTG300 MPEG generator, the PCR Stress dialog box
appears as shown in Figure 3-20. The stress tests activated from this dialog box
can only be applied when the dialog box is displayed. Any transport stream
setting changes applied by a test revert to their prior state when you exit the
dialog box.

The PCR Stress dialog box allows you to run two tests: Interval Jitter and
Value Jitter. Use the arrow buttons and hexadecimal keypad or rotary knob to set
test parameters, and then press the Interval or Value bezel buttons so that Apply
is highlighted to enable the desired test. Both jitter tests can be executing at the
same time.

Refer to Adding Jitter to PCRs on page 3-89 for more information.

Table 3-56 describes the PCR Stress dialog box parameters and Table 3-57
describes the Bezel menu commands associated with the dialog box.

Figure 3Ć20: PCR Stress dialog box

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com