Appendix D: Performance Verification

MTG100 & MTG300 MPEG Generator User Manual

DĆ13

7. Double-click the Data Store Administrator icon in the MPEG test system’s

Program Group window to start the application.

8. In the Data Store Administrator window, click the A (acquisition) command

button to open the Acquisition settings window.

9. In the Acquisition settings window, enter the following selections:

Board File

test.trp (or unique file name)

. . . . . . . . . . . . .

Partition

Single shot (this selection appears if the hard

. . . . . . . . . . . . . .

drive of the MPEG test system is partitioned)

Size

10,000,000 (bytes)

. . . . . . . . . . . . . . . . . .

Synchronization Lock

Psync

. . . .

Port

Serial ECL

. . . . . . . . . . . . . . . . . .

MSB First box

Check (this selection appears after the port is

. . . . . . . . .

set to Serial ECL)

10. In the Acquisition settings window, click Start to start the acquisition.

11. Click OK after the “Transfer is finished” message appears.

12. Select Exit/Quit from File menu or click the close box in the upper-right

corner of the application window to exit the Data Store Administrator
application.

13. Double-click the Deferred Time Analyzer icon in the MPEG test system’s

Program Group window to start the application.

14. In the Deferred Time Analyzer window, select Open from the File menu or

click the Open command button in the upper toolbar to open the Open
dialog box.

15. Select the C:\Carb0\mono\test.trp (or your unique file name) file in the

Open dialog box, and then click Open to open the test.trp file.

16. In the Deferred Time Analyzer window, select Consistency Check from the

Analysis menu to check for consistency within the stream file.

17. Verify that the No Error Found dialog box appears after the stream file is

checked by the Deferred Time Analyzer application.

18. Press the START/STOP button on the MPEG generator to stop the signal

output, and then remove the parallel interface cable from the rear panel.