Tektronix MTG100 User Manual

Page 55

background image

Tutorials

2Ć22

MTG100 & MTG300 MPEG Generator User Manual

11. Press the Keep Stress bezel button to accept the value change and close the

PCR Interval dialog box. Observe that when you changed the PCR interval
value, the color of the PCR interval value displayed to the right of the PCR
icon changed to orange to indicate a user-defined value.

12. Observe that the PCR interval is 100 ms as measured on the MPEG test

system. Figure 2-18 shows the PCR interval monitored by the Tektronix
MTS200 Series MPEG test system.

Figure 2Ć18: PCR interval monitored by the MPEG test system

13. Press the START/STOP button on the MPEG generator to stop the transport

stream output. Observe that the Output Status indicator in the status bar
changed from Running to Stopped.