beautypg.com

Tektronix MTG100 User Manual

Page 226

background image

Appendix D: Performance Verification

MTG100 & MTG300 MPEG Generator User Manual

DĆ5

This test verifies that transport stream data is output correctly from the ASI OUT
connector on the MPEG generator. The following equipment and MPEG test
signal is required for this test:

H Oscilloscope

H MPEG test system

H 75 W BNC cable

H 75 W to 50 W minimum loss attenuator

H test64.trp MPEG test signal

Perform the following procedure to verify that transport stream data is output
correctly from the ASI OUT connector on the MPEG generator:

1. Connect the ASI OUT connector on the MPEG generator to the oscilloscope

CH1 input using a 75

W BNC cable and the 75 W to 50 W minimum loss

attenuator as shown in Figure D-3.

2. Set the oscilloscope controls as indicated below:

Displayed channel

CH1

. . . . .

Vertical axis

200 mV/div

. . . . . . . . . .

Horizontal axis

5 ns/div

. . . . . . .

Horizontal position

Center

. . . .

Record length

500

. . . . . . . .

Acquire mode

Sample

. . . . . . . .

Acquire sequence

RUN/STOP button only

. . . . .

Trigger mode

Auto

. . . . . . . . .

Trigger level

0 V

. . . . . . . . .

Trigger source

CH1

. . . . . . . .

Trigger position

50 %

. . . . . . .

Trigger slope

Rising Edge

. . . . . . . . .

Trigger coupling

DC

. . . . . .

Display style

Dots

. . . . . . . . .

Input coupling

DC

. . . . . . . .

Input impedance

50

W

. . . . . .

Measure

Amplitude

. . . . . . . . . . . . .

3. Open the test64.trp file on the MPEG generator.

a. Select Open TS File... from the FILE pull-down menu.

b. In the resulting Select TS File dialog box, select the test64.trp file, and

then press the OK bezel button.

4. Press the START/STOP button on the MPEG generator to start the signal

output of the test64.trp file.

ASI Output