MTG100 & MTG300 MPEG Generator User Manual

3Ć11

Table 3Ć8: Start/End Packet dialog box parameters (Cont.)

Parameter

Description

Start Packet

Sets the number of the start packet in the transport stream.

End Packet

Sets the number of the end packet in the transport stream. The number of

(End Packet-Start Packet) is need to be more than 5000 packets.

Table 3Ć9: Bezel menu commands for the Start/End Packet dialog box

Command

Description

Default

Resets all of the dialog box settings back to the factory default settings.

Cancel

Cancels any settingchanges and closes the dialogbox.

Apply

Applies the settings to the transport stream output.

When you select the PCR Initial Value... command from the CONFIG pull-down
menu, the PCR Start Value dialog box appears as shown in Figure 3-4. Use the
arrow buttons to highlight the desired parameter, and then use the rotary knob or
hexadecimal keypad to set values. Press the OK bezel button to apply changes.

Table 3-10 describes the PCR Start Value dialog box parameters and Table 3-11
describes the Bezel menu commands associated with the dialog box.

Figure 3Ć4: PCR Start Value dialog box

Table 3Ć10: PCR Start Value dialog box parameters

Parameter

Description

Base Value

Sets the initial value for the program_clock_reference_base value. You can

set the value from 0 to 8589934591. The bracketed number represents the

number of bits for the program_clock_reference_base field.

Extension Value

Sets the initial value for the program_clock_reference_extension value. You

can set the value from 0 to 299. The bracketed number represents the

number of bits for the program_clock_reference_extension field.

PCR Start Value Dialog

Box