Appendix D: Performance Verification

DĆ18

MTG100 & MTG300 MPEG Generator User Manual

15. In the Real Time Analyzer window, click the Start Analysis toolbar button.

16. Verify that the Hierarchic view is displayed on the screen and that no error

messages appear. In addition, verify that the transmission rate is 64 Mbps
and that the transport stream packet size is 188 bytes.

17. In the Real Time Analyzer window, click the Stop Analysis toolbar button

to stop analysis.

18. Press the START/STOP button on the MPEG generator to stop the

signal output.