514

Touch probe cycles: automatic tool measurement

19

.3

Calibr

ating

the

wir

eless

T

T

449

(Cy

cle

484,

DIN/ISO:

G484)

19.3 Calibrating the wireless TT 449

(Cycle 484, DIN/ISO: G484)

Fundamentals

With Cycle 484, you calibrate the wireless infrared TT 449 tool touch

probe. The calibration process is not completely automated, because

the TT's position on the table is not defined.

Cycle run

Insert the calibrating tool.

Define and start the calibration cycle.

Position the calibrating tool manually above the center of the touch

probe and follow the instructions in the pop-up window. Ensure that

the calibrating tool is located above the measuring surface of the

probe contact.

The calibration process is semi-automatic. The TNC also measures the

center misalignment of the calibrating tool by rotating the spindle by

180° after the first half of the calibration cycle.
The calibrating tool must be a precisely cylindrical part, for example a

cylinder pin. The resulting calibration values are stored in the TNC

memory and are accounted for during subsequent tool measurement.

Please note while programming:

Cycle parameters

Cycle 484 has no cycle parameters.

The calibration tool should have a diameter of more than

15 mm and protrude approx. 50 mm from the chuck. This

configuration causes a deformation of 0.1 µm per 1 N of

probing force.

The functioning of the calibration cycle is dependent on

MP6500. Refer to your machine manual.
Before calibrating the touch probe, you must enter the

exact length and radius of the calibrating tool into the tool

table TOOL.T.
The TT needs to be recalibrated if you change its position

on the table.