beautypg.com

8 calibrate ts (cycle 460, din/iso: g460), Cycle run, Please note while programming – HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual

Page 472: See "calibrate ts (cycle 460, din/iso: g460), Cycle run please note while programming

background image

472

Touch probe cycles: special functions

17

.8 CALIBRA

TE TS (Cy

cle 460, DIN/ISO:

G460)

17.8 CALIBRATE TS (Cycle 460,

DIN/ISO: G460)

Cycle run

With Cycle 460 you can calibrate a triggering 3-D touch probe

automatically on an exact calibration sphere. You can do radius

calibration alone, or radius and length calibration.
1

Clamp the calibration sphere and check for potential collisions.

2

In the touch probe axis, position the touch probe over the

calibration sphere, and in the working plane, approximately over

the sphere center.

3

The first movement in the cycle is in the negative direction of the

touch probe axis.

4

Then the cycle determines the exact center of the sphere in the

touch probe axis.

Please note while programming:

Before programming, note the following

Pre-position the touch probe in the program so that it is

located approximately above the center of the calibration

sphere.