Touch probe cycles: automatic measurement of workpiece misalignment

14.2

BA

SIC

R

O

TA

TION

(Cy

cle

40

0,

DIN/ISO:

G40

0)

Traversing to clearance height

Q301: Definition of

how the touch probe is to move between the

measuring points:

0

: Move at measuring height between measuring

points

1

: Move at clearance height between measuring

points

Alternatively PREDEF

Default setting for basic rotation

Q307

(absolute): If the misalignment is to be measured

against a straight line other than the reference axis,

enter the angle of this reference line. The TNC will

then calculate the difference between the value

measured and the angle of the reference line for the

basic rotation. Input range -360.000 to 360.000

Preset number in table

Q305: Enter the preset

number in the table in which the TNC is to save the

determined basic rotation. If you enter Q305=0, the

TNC automatically places the determined basic

rotation in the ROT menu of the Manual Operation

mode. Input range 0 to 2999

Example: NC blocks

5 TCH PROBE 400 BASIC ROTATION

Q263=+10

;1ST POINT 1ST AXIS

Q264=+3.5 ;1ST POINT 2ND AXIS

Q265=+25

;2ND POINT 1ST AXIS

Q266=+25

;2ND POINT 2ND AXIS

Q272=2

;MEASURING AXIS

Q267=+1

;TRAVERSE DIRECTION

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+20

;CLEARANCE HEIGHT

Q301=0

;MOVE TO CLEARANCE

Q307=0

;PRESET BASIC ROTATION

Q305=0

;NO. IN TABLE