beautypg.com

5 measuring in 3-d (cycle 4, fcl 3 function), Cycle run, Please note while programming – HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual

Page 465: Cycle run please note while programming

background image

HEIDENHAIN iTNC 530

465

17

.5 MEA

S

URING IN 3-D (Cy

cle 4, FCL

3 function)

17.5 MEASURING IN 3-D (Cycle 4,

FCL 3 function)

Cycle run

Touch probe cycle 4 measures any position on the workpiece in the

probing direction defined by a vector. Unlike other measuring cycles,

Cycle 4 enables you to enter the measuring distance and feed rate

directly. Also, the touch probe retracts by a definable value after

determining the measured value.
1

The touch probe moves from the current position at the entered

feed rate in the defined probing direction. Define the probing

direction in the cycle by using a vector (delta values in X, Y and Z).

2

After the TNC has saved the position, the touch probe stops. The

TNC saves the X, Y, Z coordinates of the probe-tip center (without

calculation of the calibration data) in three successive Q

parameters. You define the number of the first parameter in the

cycle.

3

Finally, the TNC moves the touch probe back by that value against

the probing direction that you defined in the parameter MB.

Please note while programming:

Cycle 4 is an auxiliary cycle that you can only use in

conjunction with external software! The TNC does not

provide any cycle with which you can calibrate the touch

probe:

The TNC retracts the touch probe by no more than the

retraction distance MB and does not pass the starting point

of the measurement. This rules out any collision during

retraction.
Ensure during pre-positioning that the TNC moves the

probe-tip center without compensation to the defined

position!
Remember that the TNC always writes to 4 successive Q

parameters. If the TNC could not determine a valid touch

point, the 4th result parameter will have the value –1.
The TNC saves the measured values without calculating

the calibration data of the touch probe.
With function FN17: SYSWRITE ID 990 NR 6 you can set

whether the cycle runs through the probe input X12 or

X13.