Configuring the datum table, Exiting a datum table, Configuring the datum table exiting a datum table – HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual
Page 285

HEIDENHAIN iTNC 530
285
11
.3
D
A
TUM
SHIFT
with
D
at
u
m
Ta
bles
(Cy
cle
7,
DIN/ISO:
G53)
Configuring the datum table
In the second and third soft-key rows you can define for each datum
table the axes for which you wish to set the datums. In the standard
setting all of the axes are active. If you wish to exclude an axis, set the
corresponding soft key to OFF. The TNC then deletes that column
from the datum table.
If you do not wish to define a datum table for an active axis, press the
NO ENT key. The TNC then enters a dash in that column.
Exiting a datum table
Select a different type of file in file management and choose the
desired file.
This manual is related to the following products: