HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual
Page 440

440
Touch probe cycles: automatic workpiece inspection
16.9 MEA
S
URE INSIDE WIDTH (Cy
cle 425, DIN/ISO:
G425)
Measuring log
Q281: Definition of whether the TNC is
to create a measuring log:
0
: No measuring log
1:
Generate measuring log: with the standard setting
the TNC saves the log file TCHPR425.TXT in the
directory in which your measuring program is also
stored.
2
: Interrupt the program run and display the
measuring log on the screen. Resume program run
with NC Start.
PGM stop if tolerance error
Q309: Definition of
whether in the event of a violation of tolerance limits
the TNC is to interrupt program run and output an
error message:
0
: Do not interrupt program run, no error message
1
: Interrupt program run, output an error message
Tool for monitoring
Q330: Definition of whether the
TNC is to monitor the tool (see "Tool monitoring" on
page 414). Input range 0 to 32767.9; alternatively, tool
name with max. 16 characters
0
: Monitoring not active
>0
: Tool number in the tool table TOOL.T
Set-up clearance
Q320 (incremental): Additional
distance between measuring point and ball tip. Q320
is added to MP6140. Input range 0 to 99999.9999,
alternatively PREDEF
Traversing to clearance height
Q301: Definition of
how the touch probe is to move between the
measuring points:
0
: Move at measuring height between measuring
points
1
: Move at clearance height between measuring
points
Alternatively PREDEF
Example: NC blocks
5 TCH PROBE 425 MEASURE INSIDE WIDTH
Q328=+75
;STARTNG PNT 1ST AXIS
Q329=-12.5 ;STARTNG PNT 2ND AXIS
Q310=+0
;OFFS. 2ND MEASUREMENT
Q272=1
;MEASURING AXIS
Q261=-5
;MEASURING HEIGHT
Q260=+10
;CLEARANCE HEIGHT
Q311=25
;NOMINAL LENGTH
Q288=25.05 ;MAX. LIMIT
Q289=25
;MIN. LIMIT
Q281=1
;MEASURING LOG
Q309=0
;PGM STOP IF ERROR
Q330=0
;TOOL
Q320=0
;SET-UP CLEARANCE
Q301=0
;MOVE TO CLEARANCE