Bef

o

re

y

ou

star

t

w

o

rk

ing

with

to

uc

h

pr

obe

cy

cles

Touch trigger probe, probing feed rate: MP6120

In MP6120 you define the feed rate at which the TNC is to probe the

workpiece.

Touch trigger probe, rapid traverse for
positioning: MP6150

In MP6150 you define the feed rate at which the TNC pre-positions the

touch probe, or positions it between measuring points.

Touch trigger probe, rapid traverse for
positioning: MP6151

In MP6151 you define whether the TNC is to position the touch probe

at the feed rate defined in MP6150 or at rapid traverse.

Input value = 0: Position at feed rate from MP6150

Input value = 1: Pre-position at rapid traverse

KinematicsOpt: Tolerance limit in Optimization
mode: MP6600

In MP6600 you define the tolerance limit starting from which the TNC

displays a note in the Optimizing mode when the measured kinematic

data is greater than this limit value. Default: 0.05. The larger the

machine, the greater these values should be.

Input range: 0.001 to 0.999

KinematicsOpt, permissible deviation of the
calibration ball radius: MP6601

In MP6601 you define the maximum permissible deviation from the

entered cycle parameter by the calibration ball radius measured in the

cycles.

Input range: 0.01 to 0.1

The TNC calculates the calibration ball radius twice at every measuring

point for all 5 touch points. If the radius is greater than Q407 +

MP6601 an error message appears because it could be contamination.
If the radius found by the TNC is less than 5 * (Q407 - MP6601), the

TNC also issues an error message.