beautypg.com

1 general information about touch probe cycles, Method of function – HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual

Page 326

background image

326

Using touch probe cycles

13.1

Gener

al

inf

or

m

ation

about

to

uc

h

pr

obe

cy

cles

13.1 General information about

touch probe cycles

Method of function

Whenever the TNC runs a touch probe cycle, the 3-D touch probe

approaches the workpiece in one linear axis. This is also true during an

active basic rotation or with a tilted working plane. The machine tool

builder determines the probing feed rate in a machine parameter (see

"Before You Start Working with Touch Probe Cycles" later in this

chapter).
When the probe stylus contacts the workpiece,

the 3-D touch probe transmits a signal to the TNC: the coordinates

of the probed position are stored,

the touch probe stops moving, and

returns to its starting position at rapid traverse.

If the stylus is not deflected within a distance defined in MP6130, the

TNC displays an error message.

The TNC must be specially prepared by the machine tool

builder for the use of a 3-D touch probe. The machine tool

manual provides further information.
Please note that HEIDENHAIN grants a warranty for the

function of the touch probe cycles only if HEIDENHAIN

touch probes are used!

If you are carrying out measurements during program run,

be sure that the tool data (length, radius) can be used from

the calibrated data or from the last TOOL CALL block

(selected with MP7411).