1 general information about touch probe cycles, Method of function – HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual
Page 326

326
Using touch probe cycles
13.1
Gener
al
inf
or
m
ation
about
to
uc
h
pr
obe
cy
cles
13.1 General information about
touch probe cycles
Method of function
Whenever the TNC runs a touch probe cycle, the 3-D touch probe
approaches the workpiece in one linear axis. This is also true during an
active basic rotation or with a tilted working plane. The machine tool
builder determines the probing feed rate in a machine parameter (see
"Before You Start Working with Touch Probe Cycles" later in this
chapter).
When the probe stylus contacts the workpiece,
the 3-D touch probe transmits a signal to the TNC: the coordinates
of the probed position are stored,
the touch probe stops moving, and
returns to its starting position at rapid traverse.
If the stylus is not deflected within a distance defined in MP6130, the
TNC displays an error message.
The TNC must be specially prepared by the machine tool
builder for the use of a 3-D touch probe. The machine tool
manual provides further information.
Please note that HEIDENHAIN grants a warranty for the
function of the touch probe cycles only if HEIDENHAIN
touch probes are used!
If you are carrying out measurements during program run,
be sure that the tool data (length, radius) can be used from
the calibrated data or from the last TOOL CALL block
(selected with MP7411).
Y
X
Z
F
F MAX
F