Touch probe cycles: automatic measurement of workpiece misalignment

14.1

Fundamentals

14.1 Fundamentals

Overview

The TNC provides five cycles that enable you to measure and

compensate workpiece misalignment. In addition, you can reset a

basic rotation with Cycle 404:

Cycle

Soft key

Page

400 BASIC ROTATION Automatic

measurement using two points.

Compensation via basic rotation.

Page 336

401 ROT OF 2 HOLES Automatic

measurement using two holes.

Compensation via basic rotation.

Page 339

402 ROT OF 2 STUDS Automatic

measurement using two studs.

Compensation via basic rotation.

Page 342

403 ROT IN ROTARY AXIS Automatic

measurement using two points.

Compensation by turning the table.

Page 345

405 ROT IN C AXIS Automatic

alignment of an angular offset between

a hole center and the positive Y axis.

Compensation via table rotation.

Page 350

404 SET BASIC ROTATION Setting any

basic rotation.

Page 349