beautypg.com

Recording the results of measurement, 1 fundamentals – HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual

Page 411

background image

HEIDENHAIN iTNC 530

411

16.1

Fundamentals

Recording the results of measurement

For all cycles in which you automatically measure workpieces (with

the exception of Cycles 0 and 1), you can have the TNC record the

measurement results. In the respective probing cycle you can define

if the TNC is to

Save the measuring log to a file

Interrupt the program run and display the measuring log on the

screen

Create no measuring log

If you want to save the measuring log as a file, the TNC, by default,

saves the measuring log as an ASCII file in the directory from which

you run the measuring program. As an alternative, you can also send

the measuring log directly to a printer or transfer it to a PC via the data

interface. To do this, set the print function (in the interface

configuration menu) to RS232:\ (see also the User's Manual under

"MOD Functions, Setting Up the Data Interface").

All measured values listed in the log file are referenced to

the datum active during the respective cycle you are

running. In addition, the coordinate system may have been

rotated in the plane or the plane may have been tilted by

using 3-D ROT. In this case, the TNC converts the

measuring results to the respective active coordinate

system.
Use the HEIDENHAIN data transfer software TNCremo if

you wish to output the measuring log via the data

interface.

This manual is related to the following products: