344

Touch probe cycles: automatic measurement of workpiece misalignment

14.4 BA

SIC R

O

TA

TION o

ver tw

o st

uds (Cy

cle 402, DIN/ISO:

G402)

Traversing to clearance height

Q301: Definition of

how the touch probe is to move between the

measuring points:

0

: Move at measuring height between measuring

points

1

: Move at clearance height between measuring

points

Alternatively PREDEF

Default setting for basic rotation

Q307

(absolute): If the misalignment is to be measured

against a straight line other than the reference axis,

enter the angle of this reference line. The TNC will

then calculate the difference between the value

measured and the angle of the reference line for the

basic rotation. Input range -360.000 to 360.000

Preset number in table

Q305: Enter the preset

number in the table in which the TNC is to save the

determined basic rotation. If you enter Q305=0, the

TNC automatically places the determined basic

rotation in the ROT menu of the Manual Operation

mode. The parameter has no effect if the

misalignment is to be compensated by a rotation of

the rotary table (Q402=1). In this case the

misalignment is not saved as an angular value. Input

range 0 to 2999

Basic rotation / alignment

Q402: Specify whether

the TNC should compensate misalignment with a

basic rotation, or by rotating the rotary table:

0

: Set basic rotation

1

: Rotate the rotary table

When you select rotary table, the TNC does not save

the measured misalignment, not even when you have

defined a table line in parameter Q305.

Set to zero after alignment

Q337: Definition of

whether the TNC should set the display of the aligned

rotary axis to zero:

0

: Do not reset the display of the rotary axis to 0 after

alignment

1

: Reset the display of the rotary axis to 0 after

alignment

The TNC sets the display to 0 only if you have defined
Q402=1.

Example: NC blocks

5 TCH PROBE 402 ROT OF 2 STUDS

Q268=-37

;1ST CENTER IN 1ST AXIS

Q269=+12

;1ST CENTER IN 2ND AXIS

Q313=60

;DIAMETER OF STUD 1

Q261=-5

;MEASURING HEIGHT 1

Q270=+75

;2ND CENTER IN 1ST AXIS

Q271=+20

;2ND CENTER IN 2ND AXIS

Q314=60

;DIAMETER OF STUD 2

Q315=-5

;MEASURING HEIGHT 2

Q320=0

;SET-UP CLEARANCE

Q260=+20

;CLEARANCE HEIGHT

Q301=0

;MOVE TO CLEARANCE

Q307=0

;PRESET BASIC ROTATION

Q305=0

;NO. IN TABLE

Q402=0

;ALIGNMENT

Q337=0

;SET TO ZERO