beautypg.com

Cycle parameters, 17 .4 mea s uring (cy cle 3) – HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual

Page 464

background image

464

Touch probe cycles: special functions

17

.4

MEA

S

URING

(Cy

cle

3)

Cycle parameters

Parameter number for result:

Enter the number of

the Q parameter to which you want the TNC to assign

the first measured coordinate (X). The values Y and Z

are in the immediately following Q parameters. Input

range 0 to 1999

Probing axis

: Enter the axis in whose direction the

probe is to move and confirm with the ENT key. Input

range X, Y or Z

Probing angle:

Angle, measured from the defined

probing axis

in which the touch probe is to move.

Confirm with ENT. Input range -180.0000 to 180.0000

Maximum measuring range:

Enter the maximum

distance from the starting point by which the touch

probe is to move. Confirm with ENT. Input range

-99999.9999 to 99999.9999

Feed rate for measurement

: Enter the measuring

feed rate in mm/min. Input range 0 to 3000.000

Maximum retraction distance:

Traverse path in the

direction opposite the probing direction, after the

stylus was deflected. The TNC returns the touch

probe to a point no farther than the starting point, so

that there can be no collision. Input range 0 to

99999.9999

Reference system? (0=ACT/1=REF)

: Specify whether

the probing direction and the result of measurement

are to be referenced to the actual coordinate system

(ACT, can be shifted or rotated), or to the machine

coordinate system (REF):

0

: Probe in the current system and save

measurement result in the ACT system

1

: Probe in the machine-based REF system and save

measurement result in the REF system

Error mode (0=OFF/1=ON):

Specify whether the TNC

is to issue an error message if the stylus is deflected

at cycle start. If mode 1 is selected, the TNC saves

the value 2.0 in the 4th result parameter and

continues the cycle:

0

: Issue error message

1

: Do not issue error message

Example: NC blocks

4 TCH PROBE 3.0 MEASURING

5 TCH PROBE 3.1 Q1

6 TCH PROBE 3.2 X ANGLE: +15

7 TCH PROBE 3.3 DIST +10 F100 MB1

REFERENCE SYSTEM:0

8 TCH PROBE 3.4 ERRORMODE1