beautypg.com

Cycle parameters – HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual

Page 396

background image

396

Touch probe cycles: automatic datum setting

15.1

1

D

A

TUM

IN

TO

UCH

PR

OBE

AXIS

(Cy

cle

41

7,

DIN/ISO:

G41

7)

Cycle parameters

1st meas. point 1st axis

Q263 (absolute):

Coordinate of the first touch point in the reference

axis of the working plane. Input range -99999.9999 to

99999.9999

1st meas. point 2nd axis

Q264 (absolute):

Coordinate of the first touch point in the minor axis of

the working plane. Input range -99999.9999 to

99999.9999

1st meas. point 3rd axis

Q294 (absolute):

Coordinate of the first touch point in the touch probe

axis. Input range -99999.9999 to 99999.9999

Set-up clearance

Q320 (incremental): Additional

distance between measuring point and ball tip. Q320

is added to MP6140. Input range 0 to 99999.9999,

alternatively PREDEF

Clearance height

Q260 (absolute): Coordinate in the

touch probe axis at which no collision between touch

probe and workpiece (fixtures) can occur. Input range

-99999.9999 to 99999.9999, alternatively PREDEF

Datum number in table

Q305: Enter the number in the

datum or preset table in which the TNC is to save the

coordinate. If you enter Q305=0, the TNC

automatically sets the display so that the new datum

is on the probed surface. Input range 0 to 2999

New datum in TS axis

Q333 (absolute): Coordinate in

the touch probe axis at which the TNC should set the

datum. Default setting = 0 input range -99999.9999 to

99999.9999

Measured-value transfer (0, 1)

Q303: Specify

whether the determined datum is to be saved in the

datum table or in the preset table:

–1

: Do not use. Is entered by the TNC when old

programs are read in (see "Saving the calculated

datum" on page 358).

0

: Write determined datum in the active datum table.

The reference system is the active workpiece

coordinate system.

1

: Write determined datum in the preset table. The

reference system is the machine coordinate system

(REF system).

Example: NC blocks

5 TCH PROBE 417 DATUM IN TS AXIS

Q263=+25

;1ST POINT 1ST AXIS

Q264=+25

;1ST POINT 2ND AXIS

Q294=+25

;1ST POINT 3RD AXIS

Q320=0

;SET-UP CLEARANCE

Q260=+50

;CLEARANCE HEIGHT

Q305=0

;NO. IN TABLE

Q333=+0

;DATUM

Q303=+1

;MEAS. VALUE TRANSFER

X

Y

Q264

Q263

1

X

Z

Q260

Q294

MP61

40

+

Q320

1

This manual is related to the following products: