beautypg.com

HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual

Page 429

background image

HEIDENHAIN iTNC 530

429

16.6 MEA

S

. CIR

C

LE OUTSIDE (Cy

cle

422, DIN/ISO:

G422)

Measuring log

Q281: Definition of whether the TNC is

to create a measuring log:

0

: No measuring log

1

: Generate measuring log: with the standard setting

the TNC saves the log file TCHPR422.TXT in the

directory in which your measuring program is also

stored.

2

: Interrupt the program run and display the

measuring log on the screen. Resume program run

with NC Start.

PGM stop if tolerance error

Q309: Definition of

whether in the event of a violation of tolerance limits

the TNC is to interrupt program run and output an

error message:

0

: Do not interrupt program run, no error message

1

: Interrupt program run, output an error message

Tool for monitoring

Q330: Definition of whether the

TNC is to monitor the tool (see "Tool monitoring" on

page 414). Input range 0 to 32767.9; alternatively, tool

name with max. 16 characters

0

: Monitoring not active

>0

: Tool number in the tool table TOOL.T

No. of measuring points (4/3)

Q423: Specify

whether the TNC should measure the stud with 4 or

3 probing points:

4

: Use 4 measuring points (standard setting)

3

: Use 3 measuring points

Type of traverse? Line=0/Arc=1

Q365: Definition of

the path function with which the tool is to move

between the measuring points if "traverse to

clearance height" (Q301=1) is active.

0

: Move between operations on a straight line

1

: Move between operations on the pitch circle

Example: NC blocks

5 TCH PROBE 422 MEAS. CIRCLE OUTSIDE

Q273=+50

;CENTER IN 1ST AXIS

Q274=+50

;CENTER IN 2ND AXIS

Q262=75

;NOMINAL DIAMETER

Q325=+90

;STARTING ANGLE

Q247=+30

;STEPPING ANGLE

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+10

;CLEARANCE HEIGHT

Q301=0

;MOVE TO CLEARANCE

Q275=35.15 ;MAX. LIMIT

Q276=34.9 ;MIN. LIMIT

Q279=0.05 ;TOLERANCE 1ST CENTER

Q280=0.05 ;TOLERANCE 2ND CENTER

Q281=1

;MEASURING LOG

Q309=0

;PGM STOP IF ERROR

Q330=0

;TOOL

Q423=4

;NO. OF MEAS. POINTS

Q365=1

;TYPE OF TRAVERSE

This manual is related to the following products: