HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual
Page 454

454
Touch probe cycles: automatic workpiece inspection
16.13
MEA
S
URE
PLANE
(Cy
cle
431,
DIN/ISO:
G431)
Set-up clearance
Q320 (incremental): Additional
distance between measuring point and ball tip. Q320
is added to MP6140. Input range 0 to 99999.9999,
alternatively PREDEF
Clearance height
Q260 (absolute): Coordinate in the
touch probe axis at which no collision between touch
probe and workpiece (fixtures) can occur. Input range
-99999.9999 to 99999.9999, alternatively PREDEF
Measuring log
Q281: Definition of whether the TNC is
to create a measuring log:
0
: No measuring log
1:
Generate measuring log: with the standard setting
the TNC saves the log file TCHPR431.TXT in the
directory in which your measuring program is also
stored.
2
: Interrupt the program run and display the
measuring log on the screen. Resume program run
with NC Start.
Example: NC blocks
5 TCH PROBE 431 MEASURE PLANE
Q263=+20
;1ST POINT 1ST AXIS
Q264=+20
;1ST POINT 2ND AXIS
Q294=+10
;1ST POINT 3RD AXIS
Q265=+90
;2ND POINT 1ST AXIS
Q266=+25
;2ND POINT 2ND AXIS
Q295=+15
;2ND POINT 3RD AXIS
Q296=+50
;3RD POINT 1ST AXIS
Q297=+80
;3RD POINT 2ND AXIS
Q298=+20
;3RD POINT 3RD AXIS
Q320=0
;SET-UP CLEARANCE
Q260=+5
;CLEARANCE HEIGHT
Q281=1
;MEASURING LOG