Touch probe cycles: automatic workpiece inspection

16.13

MEA

S

URE

PLANE

(Cy

cle

431,

DIN/ISO:

G431)

Set-up clearance

Q320 (incremental): Additional

distance between measuring point and ball tip. Q320

is added to MP6140. Input range 0 to 99999.9999,

alternatively PREDEF

Clearance height

Q260 (absolute): Coordinate in the

touch probe axis at which no collision between touch

probe and workpiece (fixtures) can occur. Input range

-99999.9999 to 99999.9999, alternatively PREDEF

Measuring log

Q281: Definition of whether the TNC is

to create a measuring log:

0

: No measuring log

1:

Generate measuring log: with the standard setting

the TNC saves the log file TCHPR431.TXT in the

directory in which your measuring program is also

stored.

2

: Interrupt the program run and display the

measuring log on the screen. Resume program run

with NC Start.

Example: NC blocks

5 TCH PROBE 431 MEASURE PLANE

Q263=+20

;1ST POINT 1ST AXIS

Q264=+20

;1ST POINT 2ND AXIS

Q294=+10

;1ST POINT 3RD AXIS

Q265=+90

;2ND POINT 1ST AXIS

Q266=+25

;2ND POINT 2ND AXIS

Q295=+15

;2ND POINT 3RD AXIS

Q296=+50

;3RD POINT 1ST AXIS

Q297=+80

;3RD POINT 2ND AXIS

Q298=+20

;3RD POINT 3RD AXIS

Q320=0

;SET-UP CLEARANCE

Q260=+5

;CLEARANCE HEIGHT

Q281=1

;MEASURING LOG