beautypg.com

HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual

Page 341

background image

HEIDENHAIN iTNC 530

341

14.3

BA

SIC

R

O

TA

TION

fr

om

tw

o

holes

(Cy

cle

40

1,

DIN/ISO:

G40

1)

Preset number in table

Q305: Enter the preset

number in the table in which the TNC is to save the

determined basic rotation. If you enter Q305=0, the

TNC automatically places the determined basic

rotation in the ROT menu of the Manual Operation

mode. The parameter has no effect if the

misalignment is to be compensated by a rotation of

the rotary table (Q402=1). In this case the

misalignment is not saved as an angular value. Input

range 0 to 2999

Basic rotation / alignment

Q402: Specify whether

the TNC should compensate misalignment with a

basic rotation, or by rotating the rotary table:

0

: Set basic rotation

1

: Rotate the rotary table

When you select rotary table, the TNC does not save

the measured misalignment, not even when you have

defined a table line in parameter Q305.

Set to zero after alignment

Q337: Definition of

whether the TNC should set the display of the aligned

rotary axis to zero:

0

: Do not reset the display of the rotary axis to 0 after

alignment

1

: Reset the display of the rotary axis to 0 after

alignment

The TNC sets the display to 0 only if you have defined
Q402=1.

Example: NC blocks

5 TCH PROBE 401 ROT OF 2 HOLES

Q268=+37

;1ST CENTER IN 1ST AXIS

Q269=+12

;1ST CENTER IN 2ND AXIS

Q270=+75

;2ND CENTER IN 1ST AXIS

Q271=+20

;2ND CENTER IN 2ND AXIS

Q261=-5

;MEASURING HEIGHT

Q260=+20

;CLEARANCE HEIGHT

Q307=0

;PRESET BASIC ROTATION

Q305=0

;NO. IN TABLE

Q402=0

;ALIGNMENT

Q337=0

;SET TO ZERO