HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual
Page 361

HEIDENHAIN iTNC 530
361
15.2
SL
O
T
CENTER
REF
PT
(Cy
cle
408,
DIN/ISO:
G408,
FCL
3
function)
Traversing to clearance height
Q301: Definition of
how the touch probe is to move between the
measuring points:
0
: Move at measuring height between measuring
points
1
: Move at clearance height between measuring
points
Alternatively PREDEF
Number in table
Q305: Enter the number in the
datum/preset table in which the TNC is to save the
coordinates of the slot center. If you enter Q305=0,
the TNC automatically sets the display so that the
new datum is on the slot center. Input range 0 to
2999
New datum
Q405 (absolute): Coordinate in the
measuring axis at which the TNC should set the
calculated slot center. Default setting = 0. Input
range: -99999.9999 to 99999.9999
Measured-value transfer (0, 1)
Q303: Specify
whether the determined datum is to be saved in the
datum table or in the preset table:
0
: Write determined datum in the active datum table.
The reference system is the active workpiece
coordinate system.
1
: Write determined datum in the preset table. The
reference system is the machine coordinate system