Touch probe cycles: automatic datum setting

15.5 D

A

TUM FR

OM OUTSIDE OF RECT

ANGLE (Cy

cle 41

1, DIN/ISO:

G41

1)

15.5 DATUM FROM OUTSIDE OF

RECTANGLE (Cycle 411,

DIN/ISO: G411)

Cycle run

Touch Probe Cycle 411 finds the center of a rectangular stud and

defines its center as datum. If desired, the TNC can also enter the

coordinates into a datum table or the preset table.
1

Following the positioning logic (see "Executing touch probe cycles"

on page 332), the TNC positions the touch probe to the probe

starting point

1

at rapid traverse (value from MP6150). The TNC

calculates the probe starting points from the data in the cycle and

the safety clearance from MP6140.

2

Then the touch probe moves to the entered measuring height and

probes the first touch point at the probing feed rate (MP6120).

3

Then the touch probe moves either paraxially at the measuring

height or linearly at the clearance height to the next starting point

2

and probes the second touch point.

4

The TNC positions the probe to starting point

3

and then to starting

point

4

to probe the third and fourth touch points.

5

Finally the TNC returns the touch probe to the clearance height and

processes the determined datum depending on the cycle

parameters Q303 and Q305 (see "Saving the calculated datum" on

page 358)

6

If desired, the TNC subsequently measures the datum in the touch

probe axis in a separate probing and saves the actual values in the

following Q parameters.

X

Y

1

2

4

3

Parameter number

Meaning

Q151

Actual value of center in reference axis

Q152

Actual value of center in minor axis

Q154

Actual value of length in the reference

axis

Q155

Actual value of length in the minor axis